The automatic cleaning cycle is in progress. The cleaning cycle is factory set and
CELL REVERSING
cannot be adjusted. Cell Reversing does not interrupt the production of chlorine.
Salinity is displayed along with the
SALINITY
SALINITY
4.5 to 6.5 gpl (depending on pool temperature) and is too high to measure correctly
(at normal temperatures). Maintain salinity between 3.0 and 3.5 gpl. See Section 4.
The
ADD SALT
that the salinity level of the pool water is too low. Maintain Salinity between 3.0
and 3.5 gpl.
The
SERVICE and
Service Code
that requires attention. The
displayed on the front panel, displayed as a 3 digit code. The service code(s) are
displayed twice per minute with an audible alarm.
NOTE See Section 7.2, Service Codes. Problems can range from insufficient salinity to the DC cord not connected.
Audible Alarm An
when a
holding the
for 24 hours or until the power to the unit is turned off and back on whichever
comes first. However, the audible alarm will return if a new problem is detected.
NOTE The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center
power interface board.
Audible
Audible Alarm
Volume Control
control, press and hold the
will beep once when pressed, once after 10 seconds and once after 15 seconds.
Release the key after the third beep. Press the
seconds to enter the temperature change screen.
NOTE The boost cycle is normally activated after 10 seconds, however, if the key is held
The system will display a '1' followed by 'F' or 'C'. Press the
button
the alarm volume will be fully reduced. The system will occasionally show a '2' to
display the screen number. Press the arrow button B to increase the volume and the
arrow button A to reduce the volume. The volume increments from 0 to 100 in 20
steps. After each press of the arrow buttons, the alarm will activate to demonstrate
the current volume level. When the alarm volume has been adjusted to the desired
setting, press the
The change will be stored in permanent memory. If you do not wish to keep the
change, wait 5 seconds, and the change screen will 'time out' and return to normal
operation without keeping any changes to the system. Any changes made to the
alarm volume will NOT be saved if this occurs.
button
is depressed. If a reading of
(C)
indicator comes on when the flow/temp/salinity sensor determines
ADD SALT
indicator will turn on whenever the control system detects a problem
SERVICE
audible alarm (beep) sounds once per hour, and only for the first service code,
condition is detected. The alarm can be cleared by pressing and
SERVICE
button
SALINITY
alarm operation and volume control can be adjusted. To adjust volume
down until after the third beep at 15 seconds, the Boost mode will not be changed.
to move to the second parameter screen. The screen will display a 0, and
(D)
SALINITY
(grams per liter) indicator, when the
gpl
HH
indicator is accompanied by a service code
SERVICE
for 5 seconds. The audible alarm can be cleared
(C)
button
TEMPERATURE
SALINITY
button
to confirm the new alarm volume setting.
(C)
appears, the salinity is above
for 15 seconds. The system