3.8 Connection of Chlorine Generator Electronics to an AquaLink
The Jandy AquaLink RS is a multi-function pool controller that can fully control the function of the chlorine
generator. The chlorine generator user interface will display "JA" when any of its buttons are pressed while
the AquaLink RS is in control. Adjustment of the chlorine production rate or Boost mode can be controlled
from the main menu of the AquaLink RS controller (All Button, OneTouch™, or PDA). Boost mode can
also be activated from the chlorine generator user interface while the AquaLink RS is online. Refer to the
AquaLink RS Operation Manual (or AquaLink RS PDA Operation Manual) for more information. The
chlorine generator's user interface will display temperature, salinity, service codes, and LED indicators as
normal.
®
NOTE The AquaPure
and PureLink
firmware versions JJ or later.
3.8.1 Wiring AquaPure Control Center to an AquaLink RS Power Center
In the AquaLink RS power center enclosure, wire the AquaPure Control Center input power directly to the
LOAD SIDE of the filter pump relay (see Figure 14).
To Filter Pump
240 VAC
Figure 14.
Power Connection between AquaPure Control Center and AquaLink
The Jandy AquaLink RS and AquaPure use a four (4) wire connection to communicate and can be wired up
to 500 feet apart. Any outdoor rated four (4) conductor cable, minimum 22 AWG, can be used. Locate the
appropriate screw terminals on the circuit board according to Figure 15. Wire the AquaPure
4-pin terminal bar to the AquaLink RS red 4-pin terminal bar (see Figure 15).
Red, 4-Pin
Terminal Bar
OPTIONAL

AquaLink RS Power Center

Figure 15.
Communication Connection between AquaPure
System
chlorine generator electronics will communicate with AquaLink
TM
AquaLink RS Power Center
Filter Pump Relay
4 3 2 1
Chlorine Generator
Power Interface
Board
Aux. 3 Relay
To Breaker
Panel
NOTE The screw terminals are removable to aid in
installation.
IMPORTANT
Attach the wires to the like-numbered screw
terminals on both the AquaPure and AquaLink RS.