Descriptions of System Data Fields

NOTE: The following program field must be programmed before doing any zone
programming:
22 RF SYSTEM
Descriptions of System Data Fields
The blank programming form (separate insert) should be used to record the data
for this installation. Defaults for any field (where applicable) are indicated beside the
blank data entry box for each field.
The following is a list of all data fields in this control (presented in numerical order). This list
provides an explanation of each data field, and will serve as a reference for all fields in the
system.
20
INSTALLER CODE
The Installer code is used to program the system, and to assign the 4-digit
Master Security Code in the normal operation mode , via the keypad See
"Master Code" in the SYSTEM OPERATION section for the procedure. Enter
4 digits, 0–9.
21
QUICK ARM ENABLE
If enabled, the [#] key can be used instead of the security code when arming
the system. Enter 0 for disabled or 1 for enabled. This feature will
function only if the Master Code is programmed.
22
RF SYSTEM
This option is enabled if a wireless receiver is used.
Enter 1 for a 5800 RF system (5881* Series RF receivers), 4 for a 5800 RF
system, but with RF jam detection. Enter 0 if no receiver is being used.
*
5882 Series RF receivers in Canada.
23
FORCED BYPASS
This feature allows all faulted zones to be bypassed automatically.
All zones that are bypassed by this function will be displayed after the bypass
is initiated:
0 = No forced bypass; 1 = Allows automatic bypass of all open zones.
24
RF HOUSE ID CODE (2-Digit Entry)
If a 5827 or 5827BD Wireless Keypad is to be used in a 5800 RF system, a
House ID code MUST also be entered (01–31), and the keypad should be set
to the same ID. In a 5800 system with no 5827 or 5827BD wireless keypad,
enter 00 (no House ID).
25
OUTPUT RELAY MODULE
Enter 3 if relay module is being used, or 0 if not.