Introduction; Description; Features - ADEMCO N7227V5 Installation And Setup Manual

Vista security system installation and setup guide
Hide thumbs Also See for Ademco N7227V5:
Table of Contents

Advertisement

In This Section

Description

Description
The VISTA–10SE is a control that supports up to 22 hardwired and wireless zones, plus
remote keypads.

Features

Basic Hardwired Zones
Provides 6 basic hardwired zones having the following characteristics:
Zones 1-6 response time is 300–500 milliseconds.
Zone 3 programmable fast response time is 10–15 milliseconds.
EOLR supervision supporting N.O. or N.C. sensors
Zone 5 supports as many 4-wire smoke or heat detectors as can be powered from the
control).
Zones 7, 95, and 96 are keypad Panics.
Zone 8 is Duress.
Zone 9 is Tamper.
Optional Expansion Zones
Wireless Expansion:
Supports up to 16 wireless zones.
Requires the use of a 5881 (5882 in Canada) type RF receiver (with 5800 Series wireless
transmitters), as shown below.
Receiver Model
5881L (5882L*)
5881M (5881M*)
5881H (5882H*)
*
Used in Canada.
Remote Keypads
Up to 4 of any of the following keypads may be used:
Fixed-Word Keypads: 6127*, 6128, and 6137.
*
This keypad cannot be used if a 4285/4286 VIP Module is being used.
When programming from a keypad, a 6139 2-line alpha keypad must be connected (but need
not stay in the system).
Alpha Keypads 6139 (2-line alphanumeric display).
6138 (1-line alphanumeric display).
Features
No. of Zones
Up to 8
Up to 16
Up to 16
S E C T I O N

Introduction

Transmitter Type
5800
5800
5800
1
1–1