VISTA-10SE Installation and Setup Guide
For an explanation of
these formats, see the
SYSTEM
COMMUNICATION
section.
*
Can only be used if
the Primary
reporting format is
ADEMCO Contact
ID.
If reporting to a
Pager, choose from
6, 7, 8, or 9, as
desired.
14-4
46
REPORT FORMAT
Determine which format is to be used to report to the central
station. Enter 1 digit (0–9).
0 = 3+1; 4+1 ADEMCO Lo Speed Standard (this is the default)
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Lo Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting
8 = 3+1; 4+1 ADEMCO Lo Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
(Enter
as the 4th digit of 43 if 3+1 dialer reporting is to be used.)
NOTE: The maximum number of alarm and alarm restore reports
during one armed period is determined by field 92.
See field 27, which may override this field's selection.
47
SPLIT/DUAL REPORTING
Enter 0 to disable (backup report only).
Entries 1 through 9 can be made, as indicated in the table below.
Entries 6 through 9 will send a report to a pager (in addition to the
selected primary phone number), but you must enter the pager
number as the secondary phone number in field 42.
TO PRIMARY PHONE NO.
1 =
Alarms, Restore, Cancel
2 =
All except Open/Close, Test
3 =
Alarms, Restore, Cancel
4 =
All except Open/Close, Test
5 =
All reports
TO PRIMARY PHONE NO.
6 =
All reports except Open/Close
7 =
All reports
8 =
All reports
9 =
All reports except Open/Close
Will report only Users 5, 6 and 8. If using 5800 Series wireless button-
type devices, the zone number of the arm or disarm button (10–25)
will be sent as the user number.
Entries 6 through 9 will send a report to a pager (in addition to the selected
primary phone number), but you must enter the pager number as the
secondary phone number in field 42.
(1-Digit Entry)
(1-Digit Entry)
TO SECONDARY PHONE NO.
Other Reports
Open/Close, Test
All reports
All reports
All reports
*
TO PAGING NO.
(Secondary)
Alarms/Open/Close, Troubles
Alarms, Troubles
Alarms/Open/Close, Troubles
Alarms, Open/Close for users #5–25 ‡
Troubles
,