VISTA-10SE Installation and Setup Guide
È
Zone Number
10 Zone Type
Perimeter
10 Report Code
1st 01 2nd 00
10 INPUT TYPE
RF TRANS
15–2
Zone Type (ZT): Enter the Zone Type response (or change it, if
necessary).
Each zone must be assigned to a zone type, which defines the way
03
Ç
in which the system responds to faults in that zone.
Zone Type
Enter the Zone Type code (or change it, if necessary). Zone types
are listed below.
NOTE: If you enter 00, Delete Zone ? is displayed.
00 = Not used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
Press [ ] to continue.
Report Code (RC): Enter the report code. This consists of 2
hexadecimal digits, each in turn consisting of 2 numerical digits.
10
For example, for a report code of "10," enter 01 and 00. Refer to the
SYSTEM COMMUNICATION section for more information about
report codes and report code formats.
Press [ ] to continue.
Note that report codes are defaulted to 10 for use with CID reporting.
Enter Input Device type (In). Used for Input Type entry.
3 = RF (supervised RF transmitter)
3
4 = UR (unsupervised RF transmitter)
5 = Button-type RF transmitter (unsupervised)
Press [ ] to continue.
06 = 24-Hr Silent
07 = 24-Hr Audible
08 = 24-Hr Aux
09 = Fire
10 = Interior w/Delay
Transmitter inputs entered as:
"RF" (Supervised RF) Type send periodic check-in
signals, as well as fault, restore, and low-battery signals. The
transmitter must remain within the receiver's range.
"UR" (Unsupervised RF) Type send all the signals that
the "RF" type does, but the control does not supervise the
check-in signals. The transmitter may, therefore, be carried
off-premises.
"BR" (Unsupervised Button RF) Type only send fault
signals. They do not send low-battery, restore, or check-in
signals. The transmitter may be carried off-premises.
NOTE: For the built-in hardwired zones, the Input Device
type is automatically displayed as HW and cannot be edited.
20 = Arm–STAY
21 = Arm–AWAY
22 = Disarm
23 = No Alarm
Response