Sounder Connections And Power; Sounder Supervision; Testing The Sounder - ADEMCO N7227V5 Installation And Setup Manual

Vista security system installation and setup guide
Hide thumbs Also See for Ademco N7227V5:
Table of Contents

Advertisement

VISTA-10SE Installation and Setup Guide

Sounder Connections and Power

The VISTA-10SE provides a 12VDC output, which can power external alarm sounders, bells,
or sirens (see table of compatible sounders on a previous page). This output activates a
sounder when an alarm occurs.
Make connections to alarm output terminals 3 (+) and 4 (–). See Figure 12 below.
The total current drawn from the alarm output and the auxiliary power output, combined, cannot
exceed 600mA. In addition, the sounding device must be a UL Listed audible signal appliance
U L
rated to operate in a 10.2-13.8VDC range. Example: Wheelock Signals Inc. siren model 34T-12
(provides 85dBA for NFPA 74 and Standard 985).
Non-UL Installations
The total current drawn from this output cannot exceed 2 amps. A battery must be installed
because the battery supplies this current.
Going beyond the limits indicated (2 amps) will overload the power supply, and cause the
electronic circuit protecting the sounder output to trip.

Sounder Supervision

The VISTA-10SE contains a sounder (Bell) supervision option. To activate the Bell
supervision option:
1. Cut the red Bell Supervision Jumper located above terminals 2 and 3 on the control board.
See Figure 13 below.
2. Connect a 1k ohm resistor across the terminals of the last sounding device, not across the
control's terminals.
CONTROL
BOARD
_
4
ALARM
OUTPUT
+
3
Figure 12. Typical Sounder Wiring

Testing the Sounder

After you install the sounder, test the security system carefully, as follows:
1. Connect the battery wires from the control board to the battery, observing correct polarity.
2. Enter the Installer code (4111) and press the TEST (5) key on the keypad.
The external sounder should sound for 1 second if the sounder is working and proper
connections have been made. Note that if the backup battery is discharged, the sounder
does not turn on.
3. To turn off the Test mode, enter the Installer code (4111) and press the OFF key.
4. Disconnect the battery wires from the battery terminals.
5. Unplug the AC transformer from the AC outlet.
8–2
NO. 702
SIREN
_
+
CUT RED JUMPER ON
(SOUNDER) SUPERVISION
V10SE-018-V0
TERMINALS ON
CONTROL BOARD
_
4
ALARM
OUTPUT
TERMINALS
+
3
IF BELL SUPERVISION IS ENABLED (RED JUMPER
ON CONTROL BOARD IS CUT), CONNECT A 1000
OHM RESISTOR ACROSS THE EXTERNAL
CONTROL BOARD
SOUNDER, AS SHOWN BY THE DASHED LINE.
TO ENABLE BELL
DO NOT CONNECT THE RESISTOR AT THE
ALARM OUTPUT TERMINALS THEMSELVES!
Figure 13. Bell Supervision Wiring
EXTERNAL
ALARM
SOUNDER
_
1000
OBSERVE
OHM
POLARITY
EOL
+
RESISTOR
V10SE-031-V0