20
INSTALLER CODE
The Installer code is used to program the system, and to assign the 4-
digit Master security code in the normal operation mode, via the
keypad See "Master Code" in the SYSTEM OPERATION section in
the Installation Instructions for the procedure.
Enter 4 digits, 0–9.
21
QUICK ARM ENABLE
If enabled, the [#] key can be used instead of the security code when
arming the system. Enter 0 for disabled or 1 for enabled. This feature
will function only if the Master Code is programmed.
22
RF SYSTEM
This option is enabled if a wireless receiver is used.
Enter 1 for 4281 series RF receivers, 2 for 5881* series RF receivers.
Enter 0 if no receiver is being used.
*
5882 series RF receivers in Canada.
23
FORCED BYPASS FUNCTION
This feature allows all faulted zones to be bypassed automatically.
All zones that are bypassed by this function will be displayed after the
bypass is initiated:
0 = No forced bypass; 1 = Allows automatic bypass of all open zones.
24
RF HOUSE ID CODE
The House ID identifies receivers and wireless keypads in a 5700 type
system, and must be assigned (01–31).
If a 5827 or 5827BD Wireless keypad is to be used in a 5800 RF system,
a House ID code MUST also be entered (01–31), and the keypad should
be set to the same ID. In a 5800 system with no 5827 or 5827BD
wireless keypad, enter 00 (no House ID).
25
OUTPUT RELAY MODULE
Enter 3 if relay module is being used, or 0 if not.
26
VOICE (PHONE) MODULE
ACCESS CODE
The use of a 4285 Phone Module requires a 2-digit code.
Enter a 2-digit phone access code as follows: For first digit, enter any
digit from 1 to 9; for second digit, enter # +11 for " ", or # +12 for "#".
Example: If the desired access code is 7
11 (for
) is the second entry.
"00" = Phone Module disabled. Note: A "0" in either digit will disable
the 4285 Phone Module.
27
OUTPUT TO LONG RANGE RADIO
0= no, 1 = yes. If output to LRR is selected here (1), all messages that
are programmed to go to the primary telephone line receiver will also be
sent to the radio (e.g., 7720 PLUS or 7820). These messages will always
be in Contact ID format (overriding the selection in field 46). The data
line is supervised ,as well as certain functions in the radio.
If communication is lost or a trouble develops, a message will be
attempted to be sent via both radio and telephone to the central station.
Normal trouble restore report ( 71) is sent on restore of the condition.
Note: The Radio should be programmed for device address 3 on the
keypad lines.
– 13 –
firealarmresources.com
(1-Digit Entry)
(1-Digit Entry)
(1-Digit Entry)
(2-Digit Entry)
(1-Digit Entry)
(2-Digit Entry)
Default is 4-1-1-1.
Default is 0.
Default is 0 (none).
Default is 0.
Default is 00 .
Default is 0.
Default is 00.
, 7 is the first entry, and # +
(1-Digit Entry)
Default is 0.