Blackbody Installation - Motorola Avigilon H4A-ETD-KIT User Manual

Avigilon h4 thermal elevated temperature detection camera
Table of Contents

Advertisement

 3. Tighten the adjustment screws on the mount arm to secure the camera's position.
 4. In the camera web browser interface or the Avigilon Control Center software adjust the camera's
Image and Display settings. You can change the image rotation.

Blackbody Installation

Follow the
Installation Guidelines on page 9
Blackbody devices are shipped to be calibrated for 35 °C (95 °F) and ready to be used with the camera. No
further calibration is required.
 1. Open the tripod legs and use the height adjustment knobs to set the to 1.5m to 2m (5 ft - 6.5 ft).
 2. Screw the blackbody onto the tripod mount (B).
Optionally, you can screw the tilt adjuster onto the tripod and then screw the blackbody onto the tilt
adjuster (A). Adjust the tilt to ensure the blackbody is positioned at the correct angle.
Blackbody Installation
for the recommended position and height of the blackbody.
18

Advertisement

Table of Contents
loading