Commissioning; Commissioning With Io-Link In An Fdt Environment - Pepperl+Fuchs ENI58PL-S Series Manual

Programming via io-link
Table of Contents

Advertisement

ENI58PL-S***, ENI58PL-R***

Commissioning

4
Commissioning
4.1

Commissioning with IO-Link in an FDT Environment

Note!
A 5-pin M12 cordset is necessary to connect the rotary encoder to the Pepperl+Fuchs IO-Link
master. You can find suitable connection cables by visiting www.pepperl-fuchs.com and
clicking on the product page for the relevant sensor.
An IODD (IO-Link Device Description) file is available to download for programming the sensor
via IO-Link. See the product page for the relevant sensor at www.pepperl-fuchs.com.
This manual describes how to perform programming using the "PACTware" FDT frame
application into which the relevant IODD is loaded. In principle you can use other appropriate
FDT frame applications.
To integrate the IODD into PACTware, the IODD must first be converted into a Quasi-DTM using
the "IODD Interpreter DTM" software. The IODD must be recorded in the PACTware device
catalog. The "IODD Interpreter DTM" can be downloaded from www.pepperl-fuchs.com.
The "Pepperl+Fuchs PACTware Connection Wizard" is available to help you launch and
connect the rotary encoder easily. The wizard takes you through all the necessary steps for
opening a PACTware project. All of the required software components must first be installed on
the PC. Alternatively you can launch PACTware directly and add or start devices such as the IO-
Link master and the rotary encoder, the IODD, and the connection setup step by step.
Prerequisites for Commissioning
To activate the rotary encoder via IO-Link in an FDT environment, proceed as follows:
1. Download the necessary software components, such as the IODD Interpreter DTM, PACT-
ware, IO-Link-Master02-USB DTM, and the associated IODD for the rotary encoder from the
relevant product page.
2. Install the software.
3. Load the IODD in the IODD interpreter DTM to translate it for PACTware.
4. Check the connection between the rotary encoder and the IO-Link master.
Setting Up Sensor Communication Using PACTware via the "Pepperl+Fuchs
PACTware Connection Wizard"
In addition to the aforementioned software components, the "Pepperl+Fuchs PACTware
Connection Wizard" must be installed on the PC. The rotary encoder and IO-Link master must
also be connected to the PC.
Double-click the "Pepperl+Fuchs PACTware Connection Wizard" icon.
PACTware and the associated DTM/IODD are loaded and the connection to the rotary
encoder is automatically established.