6
Warning or error message at abnormal stopping
7
Overload pre-warning
8
Overtemperature alert signal power stage
9
External Overtemperature alert signal motor
11
Overtemperature alert signal interior OHI
12
Cable breakage 4...20 mA on analog input 1
14
max. constant current (Stall, CP.25) exceeded
15
max. ramp current (LA-Stop, CP.24) exceeded
16
DC-braking active
20
Actual value = set value (CP.3 = Fcon; rcon; not at noP, LS, error, SSF)
21
Accelerate (CP.3=FAcc, rAcc, LAS)
22
Decelerate (CP.3 = FdEc, rdEc, LdS)
23
Real direction of rotation = set direction of rotation
24
Utilization (CP.6) > switching level
25
Active current > switching level
26
Intermediate circuit voltage (CP.7) > switching level
27
Real value (CP.1) > switching level
28
Set value (CP.2) > switching level
31
Absolute set value at AN1 > switching level
32
Absolute set value at AN2 > switching level
34
Set value at AN1 > switching level
35
Set value at AN2 > switching level
40
Hardware current limit activated
41
modulation on
44
Inverter status > switching level
45
Power stage temperature > switching level
46
Motor temperature > switching level
47
Ramp output value > switching level
48
Apparent current (CP.4) > switching level
49
Forward running (not at nOP, LS, abnormal stopping or error)
50
Reverse running (not at nOP, LS, abnormal stopping or error)
63
Absolut ANOUT1 > switching level
64
Absolut ANOUT2 > switching level
65
ANOUT1 > switching level
66
ANOUT2 > switching level
70
Driving current active (safety relay)
73
Absolute active power > switching level
74
Active power > switching level
No listed values are only for application mode.
CP.34 Source of rotation direction
The source rotation setting and the mode of evaluating the rotation setting is defined with
this parameter (Enter-Parameter). With CP.34 one does not modify the rotation source of
the fixed frequencies (CP.19...21).
Value Direction of rotation
0/1
only application mode
2
Setting by way of terminal strip forward/reverse; negative set values are set to
zero (factory setting).