Cleaning Instructions - H.C Duke & Son Electro Freeze GENESIS Series Operator’s Manual With Illustrated Parts List

Soft serve freezer
Hide thumbs Also See for Electro Freeze GENESIS Series:
Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Model GEN-5099
7.3

Cleaning Instructions

NOTE: It is your responsibility to
be aware of, and conform to, the
requirements for meeting federal, state
and local laws concerning the frequency
of cleaning and sanitizing the freezer.
for washing, rinsing, and sanitizing parts
removed from the freezer, per applicable
local health codes. Also prepare a clean
surface to air-dry all parts.
Do not use unapproved sanitizer
or laundry bleach. These materials
may contain high concentrations of
chlorine and will chemically attack
freezer components.
Figure 7-6 Clean head ports and
24
CAUTION
To prevent bacteria growth,
remove all O-rings when
cleaning. Failure to do so
could create a health haz-
ard.
1. Prepare a three-compartment sink
 Important:
openings with brush.
CAUTION
Electrical shock hazard.
Do not splash water on
switches or allow water
to flow onto electrical
components inside the
machine.
NOTE: The sanitizer should be mixed
according to the manufacturer's
instructions to yield 100PPM available
chlorine solution (example: Stera-Sheen
Green Label.) Use warm water (100° to
110°F or 38° to 43°C) to wash, rinse, and
sanitize.
2. Wash all parts removed from the
freezer thoroughly with dish detergent.
Clean the following parts with the
appropriate supplied brush:
a. The mix tanks, pickup tube
assemblies, hoses, and probes.
b. The head plunger openings,
plunger ports, O-ring grooves, dispense
nozzle mounting rings, and mix ports, as
shown in figure 7-6.
c.
The beater shaft cup seals,
plastic washers, and O-rings. The plunger
O-ring grooves and nozzles, as shown in
figure 7-7.
d. The air bleed plug O-ring
grooves.
Figure 7-7 Clean O-ring grooves,
seal and nozzle with brush.
– continued
185242

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Electro freeze genesis gen-5099

Table of Contents