ELECTRO FREEZE Soft Serve Model GEN-5099
3
Specifications
3.1
Particulars
Always check and verify voltage and amperage on the data
plate located on the back panel of each freezer.
185242
GEN-5400
Width (in/cm) ...................................................... 26/66
Height (in/cm) (Water cooled) ....................... 67.5/171
Height (in/cm)(Air cooled) ................................ 68/173
Depth (in/cm) .................................................. 36.5/93
Weight (lbs/kg) ............................................... 847/385
Compressor Cylinder (2)* ...........2 HP/19000 BTUH
Compressor Cabinet (1)* .............1/6 HP/650 BTUH
Beater Motor ........................................ 2 HP/1.5 kw
Refrigerant ........................................................ 404a
Charge** ..............................................3.75 lb/1.7 kg
Mix Container*** (2) ..................... 24 Qts/22.7 Liters
Cylinder (2) ........................................ 4 Qts/3.8 Liters
Noise: The Steady acoustic pressure level, for both air
cooled and water cooled freezers, is less than 70dB(A).
Water Cooled units: Water consumption increases if
temperature of entering water is above 20°C (65°F)
*Contact factory for other voltages.
**for each side
*** Do not add mix above line marked on side of mix
tank wall.
2.2 kw (Motor)
3.2 kw (Cooling)
125w (Motor)
190kw (Cooling)
5