ELECTRO FREEZE Soft Serve Model GEN-5099
7.2 Disassembly Instructions
7. Remove the handle pin (9),
handle (10&12), plunger (4&8) and nozzle
(13) from the dispense head.
8. Remove O-rings (3) from the
dispense head and O-rings (2) from the
plungers (4&8).
9. Remove the cup seal (figure 7-3)
and O-ring from the plastic washer on the
shaft seal assembly.
10. Remove mix containers, covers,
and low mix probes
11. Remove the MTS cover.
12. Remove MTS hose assemblies
from the Mix Transfer Systems as follows
(figure 6-4):
hose,
slide hose assembly out of roller support
housing.
12. Disassemble the MTS hose
assemblies as shown in figure 7-5.
Figure 7-3 Shaft Seal
185242
a. loosen the hand knob,
b. swing back the shoe clamp,
c. swing open the roller shoe,
d. loosen the clamp on braided
e. pull tube off cylinder inlet and
CUP SEAL
WASHER
O-RING
(continued)
Figure 7-4 MTS
Figure 7-5 MTS Hose Assembly
23