ELECTRO FREEZE Soft Serve Model GEN-5099
13 Troubleshooting Tables
PROBLEM
PROBABLE CAUSE
1.
Compressor and
beater motor do
not operate when
2. Component failure.
dispensing.
1. Cabinet setting too low.
2. Defective thermostat.
Cabinet too
cold. (below
35°F [1.7°C])
3. Cabinet solenoid stuck open
4. Cabinet expansion valve set too low.
1.
2.
3. Cabinet switch defective.
Mix sours in
4. Door switch defective.
cabinet.
5.
6. Faulty time delay.
7. Suction pressure too low.
46
Spigot switch(es) defective or out of
adjustment.
Cabinet thermostat defective, set too
warm or tuned off.
Cabinet solenoid defective (does not
open).
Cabinet compressor contactor coil open
(mix sours in night mode only.
(continued)
REMEDY
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
Contact your Electro Freeze
5.
Distributor for service.
Contact your Electro Freeze
6.
Distributor for service.
Contact your Electro Freeze
7.
Distributor for service.
185242