Error number
Reason
Err 40, 41, 45
Fatal
was expected.
Err 42
The output current is too high.
Err 43
The requested output current requires too high a
voltage.
Err 44
Fatal
thermal cut out which operates at approximately
65°C to 70°C depending on conditions.
Err 46
The maximun average power output has been
exceeded. Reduce the brightness in the
configuration.
Err 47
The controller was unable to reach a stable output
for this light. Try reducing the brightness in the
configuration.