GARDASOFT TR-HT2 Series User Manual page 74

Led controller
Table of Contents

Advertisement

Event number
1 to 127
128
129
130
131
132
138
139
140
13.2.6 Error codes
Some error codes are displayed on the TR-HT's front panel: these are also
shown.
Error number
Err 1
Err 2
Err 3
Err 4
Err 5
TR-HT2xx LED Controller - User Manual
Reason
An error has occurred. See Section 13.2.6, Error
codes.
A light has been connected and is working.
A light has been connected but does not have a
current or voltage rating.
An over temperature error has occurred.
An over current error has occurred.
An error has occurred while autosensing the rating
of a light.
SafePower trainup has completed.
SafePower trainup has failed or been cancelled.
In switched mode, the light has been turned off
because the duty cycle is too high.
Reason
A parameter value is invalid.
Command not recognised.
A numeric value is in the wrong format.
Wrong number of parameters.
This is a warning, not an error. One of the
parameters is out of range and the value of that
parameter has been adjusted. For example,
sending an RT command with a delay of 0μs returns
an 'Err 5'. The command is accepted, but the delay
is set to the minimum allowed value.
74

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr-ht220-50Tr-ht260-50

Table of Contents