GARDASOFT RT 20 Series User Manual

GARDASOFT RT 20 Series User Manual

Lighting controllers

Advertisement

RTxxx LED
Lighting Controllers
Issue 015
User manual
www.gardasoft.com

Advertisement

Table of Contents
loading

Summary of Contents for GARDASOFT RT 20 Series

  • Page 1 RTxxx LED Lighting Controllers Issue 015 User manual www.gardasoft.com...
  • Page 2 Deliberate acts of endangerment and vandalism are not covered by this document and must be considered by the installer. While care has been taken in the preparation of this document Gardasoft Vision Ltd will not accept any liability for consequential loss of any kind except those required by law.
  • Page 3: Table Of Contents

    RTxxx LED controllers -User Manual Contents Getting started Summary of features Safety Heat Electrical General Installation guidance (disclaimer) Sicherheit Wärme Elektrik Allgemein Installationsanleitung (Haftungsausschluss) Sécurité Chaleur Électricité Généralités Guide d'installation (clause de non-responsabilité) Mounting the RTxxx Environmental considerations Electrostatic discharge Connections Power supply Lighting output Trigger inputs...
  • Page 4 RTxxx LED controllers -User Manual Setting the internal trigger timer Using the key lock 9.10 Viewing the trigger status 9.11 Viewing the output current Ethernet communication(RT220, RT420, RT820F) 10.1 Connection 10.2 IP Address 10.2.1 DHCP 10.2.2 Fixed IP address 10.3 Automatic sensing Webpage configuration (RT220, RT420, RT820F) 11.1 Main page...
  • Page 5: Getting Started

    (RT220, RT420, RT820F), and Section 12, Command configuration. Visit www.gardasoft.com for application notes on this product. There is also a Support page which has information on troubleshooting problems. Summary of features Throughout this manual, references to the RTxxx refer to all variants in the RTxxx range unless otherwise stated.
  • Page 6 RTxxx LED lighting controllers - User Manual The table below lists the features on each model: Number Pushbutton Fast Ethernet RS232 setup setup setup pulsing channels RT200 RT220 RT260 RT200F RT220F RT260F RT420 RT460 RT420F RT460F RT820F RT860F — —...
  • Page 7: Safety

    RTxxx LED lighting controllers - User Manual Safety Read this before using the RTxxx. Always observe the following safety precautions. If in doubt, contact Gardasoft Vision Ltd. The following symbols are used in this guide: Warning: Read the instructions to understand the possible hazards.
  • Page 8 RTxxx LED lighting controllers - User Manual The Power Supply Unit (PSU) used to energise the RTxxx must provide double insulation/reinforced isolation from mains electricity and pro- tected against short circuits and overloads. We recommend using a PSU that limits its output current to the appropriate rating of the con- troller by design, by setting the current limit on the supply (if pos- sible), or through over current protection.
  • Page 9: General

    While Gardasoft Vision Ltd has taken every care in the preparation of this advice, Gardasoft Vision Ltd accept no liability for damages of any kind except those required by law. Deliberate acts of endangerment and vandalism are not covered by this document and must be considered by the installer.
  • Page 10: Sicherheit

    Sicherheit Bitte lesen Sie vor Verwendung des RTxxx diese Informationen. Beachten Sie immer die folgenden Sicherheitshinweise. Wenden Sie sich im Zweifelsfall an Ihren Händler oder Gardasoft Vision. Die folgenden Symbole haben die folgende Bedeutung: Warnung: Lesen Sie die Hinweise, um eine mögliche Gefahr zu verstehen.
  • Page 11 RTxxx LED lighting controllers - User Manual Standard IEC 60950-1 zugelassen sein. Alle anderen Geräte, die an die Trigger- oder andere Ports angeschlossen sind, müssen ebenfalls durch eine doppelte Isolierung/verstärkte Isolierung vom Stromnetz getrennt sein. Das Netzgerät, das zur Stromversorgung des RTxxx dient, muss durch eine doppelte Isolierung/verstärkte Isolierung von der Stromversorgung getrennt sein und gegen Kurzschlüsse und Überlastungen geschützt sein.
  • Page 12: Allgemein

    Diese Informationen dienen nur zur Orientierung. Installationstechniker müssen ihre eigene spezifische Risikobewertung für die jeweilige Installation durchführen. Auch wenn Gardasoft Vision Ltd diese Empfehlung mit größter Sorgfalt erstellt hat, übernimmt Gardasoft Vision Ltd keine Haftung für Schäden jeglicher Art, außer in dem gesetzlich erforderlichen Maße.
  • Page 13: Sécurité

    Sécurité Lisez ce document avant d'utiliser le RTxxx. Respectez les mesures de sécurité suivantes en toutes circonstances. En cas de doute, contactez votre distributeur ou Gardasoft Vision. Les symboles ci-dessous auront la signification suivante: Attention: Lisez les instructions pour comprendre quels sont les risques éventuels.
  • Page 14 RTxxx LED lighting controllers - User Manual branchés aux déclencheurs ou à d'autres ports doivent aussi posséder une isolation double/renforcée pour être protégés de l'alimentation secteur. Le boîtier d'alimentation utilisé pour mettre sous tension le RTxxx doit fournir une isolation double/renforcée pour isoler le RTxxx de l'alimentation secteur, et le protéger des courts-circuits et des surcharges.
  • Page 15: Généralités

    Ces informations sont seulement à titre indicatif. Les installateurs doivent effectuer leur propre évaluation des risques, pour chaque installation. Même si Gardasoft Vision Ltd a préparé minutieusement ces conseils, Gardasoft Vision Ltd décline toute responsabilité pour tout dommage, quel qu'il soit, à l'exception de ceux requis par la loi. La mise en péril volontaire ainsi que les actes de vandalisme ne sont pas...
  • Page 16: Mounting The Rtxxx

    RTxxx LED lighting controllers - User Manual Mounting the RTxxx In order to provide fixing points to mount the unit onto a flat surface or bracket, insert M3 nuts into one or more of the slots in the base, see the illustration below. The quantity and position of these nuts depends on the user’s requirements.
  • Page 17 RTxxx LED lighting controllers - User Manual The illustration below shows the dimensions of an RT4xx controller: — —...
  • Page 18: Electrostatic Discharge

    RTxxx LED lighting controllers - User Manual The illustration below shows the dimensions of an RT8xxF controller: Electrostatic discharge Electrostatic discharge (ESD) can damage equipment and impair the electrical circuitry inside your RTxxx. ESD damage occurs when electronic components are improperly handled and can result in complete or intermittent failures.
  • Page 19: Connections

    RTxxx LED lighting controllers - User Manual Connections Section 13, Reference information for information about connection ratings Power supply In the unlikely event of a fault in the RTxxx, the maximum power dissipation in the unit can be: Power supply voltage x Max current delivered by power supply Either limit the power supply output current so that the RTxxx cannot dissipate more than 30W, or mount the unit in a fire enclosure.
  • Page 20 RTxxx LED lighting controllers - User Manual lighting connections must be shielded so they cannot be being touched both within the light and along the whole length of the cable. The lighting connections to an RTxxx are made through 4-way connectors as shown below: Ensure you set the current or voltage rating of your light before you connect it, see Section 8, Lighting...
  • Page 21 RTxxx LED lighting controllers - User Manual RT4xx — —...
  • Page 22: Trigger Inputs

    RTxxx LED lighting controllers - User Manual RT8xxF Trigger inputs The trigger inputs are opto-isolated 3V to 24V input, drawing a minimum of 3mA. The table overleaf describes the pin allocations for the RTxxx controllers’ trigger connectors: — —...
  • Page 23: Power Output

    RTxxx LED lighting controllers - User Manual Note: All RTxxx controllers are fitted with Connector ET12. Connector ET34 is present on the RT4xx and RT8xxF series controllers. Connectors ET56 and ET78 are present only on RT8xxF controllers. Connector Connector Connector Connector ET12 ET34 ET56...
  • Page 24: Connectors

    RTxxx LED lighting controllers - User Manual Connectors The RTxxx packaging includes mating connectors for the power supply input, digital outputs, 12V power output, and lighting output. Should spare parts be required these can be obtained from Würth (www.we-online.com), Farnell (www.farnell.com), or Newark (www.newark.com).
  • Page 25: General Description

    RTxxx LED lighting controllers - User Manual General description The RTxxx series of current controllers provide repeatable intensity control of LED lighting for machine vision applications. This includes the intensity control, timing and triggering functions required for machine vision systems. LED lighting needs a constant current supply as small variations in voltage can cause large variations in light output.
  • Page 26: Pulsed Output

    RTxxx LED lighting controllers - User Manual Mode Trigger input Output Switched Trigger = off Output is off Trigger = on Output is on Selected Trigger = off Output is continuous bright- Trigger = on ness 2 Output is continuous bright- ness 1 Pulsed Trigger rising...
  • Page 27: Fault Detection

    RTxxx LED lighting controllers - User Manual The duty cycle is limited by ignoring triggers which are too soon after the previous trigger. For example, if the brightness is set to 250%, then the RTxxx does not allow pulses greater than 10ms long. With 10ms pulses, if a trigger occurs within 50ms of a previous trigger (so that the duty cycle would be greater than 20%) the trigger is ignored.
  • Page 28: Light Characterisation

    RTxxx LED lighting controllers - User Manual Comms Display error Reason error number Current output is too low. This may Err 21 be because the light has become disconnected. The lighting required more than Err 22 the maximum available current for the voltage rating.
  • Page 29: Cold Start

    RTxxx LED lighting controllers - User Manual maintain the target current. This will compensate for any inaccuracies such as temperature drift in the controller. If the output current is less than 100mA, the adjustments the feature imposes can have a significant effect on the lighting brightness. If some flickering is seen, it is recommended that the current adjust feature is turned off.
  • Page 30: Lighting Setup

    RTxxx LED lighting controllers - User Manual Lighting setup The rating of the light must be set by the user. This rating is the supply to the lighting that should be used to get 100% continuous brightness from the light. The RTxxx is compatible with both current and voltage rated lighting.
  • Page 31: Front Panel Configuration (Rt200)

    RTxxx LED lighting controllers - User Manual Front panel configuration (RT200) Using the front panel keypad, you can set the configuration for each channel, set a keylock code so unauthorised users cannot change any settings, set the internal trigger time, view trigger status, and set the voltage or current rating.
  • Page 32: Setting The Light Rating

    RTxxx LED lighting controllers - User Manual Display Select to: Set up the internal trigger View the trigger status View the output current Set the lighting rating During the setup of a channel, the trigger can be set to active high or low according to the P flag setting.
  • Page 33: Setting Up Continuous Output

    RTxxx LED lighting controllers - User Manual If your light is voltage rated, use the p and q buttons to select Uol and press the SEL  button. For current rated lights, use the p and q but- tons to set the rating in Amps, and press the SEL button.
  • Page 34 RTxxx LED lighting controllers - User Manual Use the p and q buttons to select SCo and press the SEL  button. bri is displayed. Press the SEL  button to select the light's intensity. Use the p and q buttons to set the intensity from 1% to 99.9%.
  • Page 35: Setting Up Switched Output

    RTxxx LED lighting controllers - User Manual Continuous output is set up on the RT200. Setting up switched output Switched output is when the light remains on for as long as there is a signal on the trigger input. Press and hold SEL  for one second , displayed.
  • Page 36 RTxxx LED lighting controllers - User Manual trg is displayed. Press the SEL button. Use the p and q buttons to select the trigger ( IP1 or IP2 ) you want to set up, and press the SEL button. To set the trigger polarity so that it is active high, press the SEL  button with F P displayed.
  • Page 37: Setting Up Selected Output

    RTxxx LED lighting controllers - User Manual If you wish to disable the error detection, use the p and q buttons to select F-E , and press the SEL button. Switched output is set up on the RT200. Setting up selected output Set up selected output if you want to switch between to lighting levels on a trigger input.
  • Page 38 RTxxx LED lighting controllers - User Manual Use the p and q buttons to set the first intensity level from 1% to 99.9%. The default setting is 50%. Press the SEL  button. b2 is displayed. Press the SEL  button to set the second intensity level.
  • Page 39: Setting Up Pulsed Operation

    RTxxx LED lighting controllers - User Manual To set the trigger polarity so that it is active high, press the SEL  button with F P dis- played. Or... If you wish to set the trigger polarity so that it is active low, use the p and q buttons to select F-P and press the SEL button.
  • Page 40 RTxxx LED lighting controllers - User Manual The channel you want to set up is displayed. Press the SEL  button. Use the p and q buttons to select SPu and press the SEL  button. bri is displayed. Press the SEL  button to set the lighting intensity.
  • Page 41 RTxxx LED lighting controllers - User Manual PUL is displayed. Press the SEL button to set up the pulse width as described in Section 9.7, Setting time periods. Press the SEL button. rEt is displayed. Press the SEL  button to set up the retrigger time as described in Section 9.7, Setting time...
  • Page 42: Setting Time Periods

    RTxxx LED lighting controllers - User Manual If you wish to set the trigger polarity so that it is active low, use the p and q buttons to select F-P and press the SEL button. To set the error detection, press the SEL  button with F E displayed.
  • Page 43 RTxxx LED lighting controllers - User Manual Exponent Multiplier Number Range of values value format Values are displayed in 0.01 9.99 seconds from 10ms to 5s in steps of 10ms. Values are displayed in 0.001 999. milliseconds from 1ms to 999ms in steps of 1ms. Values are displayed in 0.0001 99.9...
  • Page 44 RTxxx LED lighting controllers - User Manual E-3 is displayed. Press the SEL button to enter time values from 1ms to 999ms. Use the p and q buttons to select the required value in steps of 1ms. Press the SEL  button. E-4 is displayed.
  • Page 45: Setting The Internal Trigger Timer

    RTxxx LED lighting controllers - User Manual Use the p and q buttons to select the required value in steps of 0.01ms. Press the SEL  button. E-6 is displayed. Press the SEL button to enter time values from 1μs to 999μs. Use the p and q buttons to select the required value in steps of 1μs.
  • Page 46: Using The Key Lock

    RTxxx LED lighting controllers - User Manual OFF is displayed. Press the SEL  button to end the sequence. Or... Use the p and q buttons to select On and press the SEL  button. The internal trigger is running with the parameters set up in Section 9.6, Setting up pulsed operation.
  • Page 47 RTxxx LED lighting controllers - User Manual To set up the lock code, use the p and q buttons to select Lc . Press the SEL  button. 0 is displayed. Use the p and q buttons to set a lock code value from 0 to 255, and press the SEL  button.
  • Page 48: Viewing The Trigger Status

    RTxxx LED lighting controllers - User Manual Use the p and q buttons to enter the lock code and press the SEL button. CH1 is displayed and the RT200 keypad is unlocked. If the code entered is incorrect, LOC is displayed. 9.10 Viewing the trigger status You can view the trigger input status and whether the light is pulsing when the RT200 is set to pulse mode.
  • Page 49 RTxxx LED lighting controllers - User Manual To view the output current, press the SEL button for one second and is displayed. Follow the keystrokes below: Use the p and q buttons to select UAL and press the SEL button. CH1 is displayed. Use the p and q buttons to select CH2 if you wish to view the output current from channel 2.
  • Page 50: Ethernet Communication(Rt220, Rt420, Rt820F)

    You may need to ask your network administrator for advice about setting up the Ethernet connection. Ethernet set up is not affected by cold booting the RTxxx. See Application note APP923 (available from www.gardasoft.com) for troubleshooting Ethernet problems. 10.1 Connection The Ethernet link uses a 10Base-T connection on an RJ45 connector.
  • Page 51: Dhcp

    RTxxx LED lighting controllers - User Manual GardasoftMaint allows you to view the controllers on your network, change their IP addresses and upgrade their firmware if it becomes necessary. In the messaging section of GardasoftMaint, you can communicate with your controller using the commands explained in Section 12, Command configuration.
  • Page 52: Fixed Ip Address

    On the first two events, the message is broadcast. On the third it is a reply to a single IP address. An enquiry message is a UDP packet from source port 30310, destination port 30311 with the message body ‘Gardasoft Search’ (8-bit ASCII, 13 characters).
  • Page 53: Webpage Configuration (Rt220, Rt420, Rt820F)

    RTxxx's webpages. You can also type the controller’s IP address (displayed in GardasoftMaint) into your web browser, which will display the Main screen. GardasoftMaint software is available from www.gardasoft.com/Downloads. 11.1 Main page The main page (shown below) is the first to open when you access the RTxxx's webpages.
  • Page 54: Configuration Page

    RTxxx LED lighting controllers - User Manual 11.2 Configuration page There is one configuration page for each output channel, as shown below. To refresh this page it is important that you click the Refresh Ø button on the webpage( ) rather than on your web browser. When configuration changes are submitted, the URL includes the new configuration, so refreshing the page re-submits the URL.
  • Page 55: General Setup Page

    RTxxx LED lighting controllers - User Manual 11.3 General setup page The General Setup page allows you to set up or clear the webpage's password and set up the internal trigger. You can also enter any Ethernet command from Section 12, Command configuration.
  • Page 56: Command Configuration

    RTxxx LED lighting controllers - User Manual Command configuration The RTxxx can be configured through the Ethernet connection using UDP or TCP/IP. You can download sample C++, C#, VB.NET code from www.gardasoft.com to allow configuration. 12.1 Ethernet configuration (RT220, RT420, RT820F) For TCP, commands from a host should be sent to destination port 30313 with replies sent to destination port 30312.
  • Page 57: General Commands

    RTxxx LED lighting controllers - User Manual Numeric parameters are separated by a comma ( , ). For a parameter which is a time period, the default units are milliseconds. ‘s’, ‘ms’ or ‘us’ can be added to the end of the number to indicate seconds, milliseconds or microseconds.
  • Page 58 RTxxx LED lighting controllers - User Manual For example: TT1,200 Set the internal trigger to 200ms (5Hz) TT1,500US Set the internal trigger to 500µs (2KHz) Save the settings to memory Once the settings are saved to memory they are retained when the unit is switched off.
  • Page 59 RTxxx LED lighting controllers - User Manual Input trigger (set using the RP command) Flags (set using the RE command) Rating of the light (after SafeSense has suc- cessfully completed sensing the light) Rating of the light (set using the VL command). When using Ethernet, use the following forms of the ST command: Reports the general settings.
  • Page 60: Lighting Channel Commands

    RTxxx LED lighting controllers - User Manual Clear any Errors If Ethernet messages are not enabled, the last event or error number can be read by this command. Any error displayed on the unit is cleared, so if there was a lighting error, the RTxxx resumes auto-sensing on that channel.
  • Page 61 RTxxx LED lighting controllers - User Manual Where: c = output channel (1 to 2,4 or 8, depending on model) m - maximum expected brightness (50% to 999%) Setting m = 0 turns off automatic sensing. The PQ  command returns the current maximum brightness for automatic sensing. Set continuous mode The output is set to continuous mode at a percentage of full brightness.
  • Page 62 RTxxx LED lighting controllers - User Manual Set pulse mode The output can be set up to pulse on a trigger input. The delay from trigger to the start of the pulse, the length of the pulse and the brightness are configurable. An error is generated if the brightness setting requires a current greater than 20A or if the combination of pulse width and setting is not allowed.
  • Page 63: Command Summary

    RTxxx LED lighting controllers - User Manual RPc,p Where: c = output channel (1 to 2, 4 or 8, depending on model) p = trigger input (1 or 2) This command can be used to override the state of an input. The override is cancelled as soon as an edge is detected on the input.
  • Page 64 RTxxx LED lighting controllers - User Manual Command Example Effect Trigger channel 2. Show configuration for channel 2. — —...
  • Page 65: Reference Information

    RTxxx LED lighting controllers - User Manual Reference information This section contains the specification for the RTxxx and any restrictions on its use. Error and event codes are also listed. 13.1 Specification The RTxxx range of controllers has a 2 amp option with a '-2' suffix, and a fast pulsing option with an 'F' suffix.
  • Page 66: Restrictions

    RTxxx LED lighting controllers - User Manual 13.2 Restrictions The maximum output power for an RT2xx is 30W per channel or 40W total. For an RT4xx, it's 30W per channel or 50W total. The maximum output power for an RT8xxF is 30W per channel or 100W total. The following timings and restrictions are applied whenever settings are saved (using the AW command).
  • Page 67: Error Codes

    RTxxx LED lighting controllers - User Manual Special note for RT8xxF controllers: If you need to generate a variety of output currents, the highest current loads should be connected to the low-numbered output channels. For example CH1, CH2... This minimises the spread of high currents on the internal PCB and helps to maintain a low temperature rise in the unit.
  • Page 68: Fatal Error Codes

    RTxxx LED lighting controllers - User Manual Error num- Reason Err 36 The output is short circuit. Err 42 The output current is too high. The voltage required for the lighting has Err 37 increased too much. Check for ageing of the light- ing or a failed LED.
  • Page 69 RTxxx LED lighting controllers - User Manual Event num- Reason A light has been connected and is working. A light has been connected but doesn’t have a current or voltage rating. An over temperature error occurred. An over current error occurred. An error has occurred while autosensing the rating of a light.
  • Page 70 RTxxx LED lighting controllers - User Manual Issue v015 - August 2020 © Copyright 2020 Gardasoft Vision Ltd Gardasoft LLC Gardasoft Vision Ltd Oak Ridge Road Trinity Court Weare Buckingway Business Park New Hampshire Cambridge CB24 4UQ UK 03281 USA tel: +44 1954 234970 tel: +1 603-657-9026 www.gardasoft.com...