GARDASOFT TR-HT2 Series User Manual page 33

Led controller
Table of Contents

Advertisement

Mode
Mode
name
10
Buffer T
(buF)
11
Buffer E
(buE)
12
Burst E
(brE)
13
Counter
(Cou)
14
Min Pulse
Trig
(iPF)
15
Max Pulse
Trig
(APF)
TR-HT2xx LED Controller - User Manual
Operation
Buffer an input by making the output the
same signal as the input. If the Gate Input
parameter is set, then the gate input signal
enables the output – if the Gate Input
parameter is off, then the output is off. Flag O
inverts the output and Flag G inverts the gate
input.
The output can be delayed by a fixed time
given by the <Pulse Delay> parameter.
Note: Apply any Gate Input before the Pulse
Delay.
The E flag can be set to indicate when the
output changes state.
Same as buF mode, except the output signal
can be delayed by a given number of encoder
pulses.
Same as bur mode, except the pulse width
and pulse spacing is a given number of
encoder pulses.
Sets the output as a counter. The count does
not start until the leading edge of the gate
input. After that, the counter counts <Pulse
Delay> leading edges on the trigger input. The
output is then pulsed for a period of <Pulse
Width>.
The trigger pulse must be a minimum width to
cause an output pulse. The output will pulse if
the trigger signal stays valid for <Pulse Delay>
time. The output pulse starts when the <Pulse
Delay> time has completed (before the end of
the trigger pulse). The output is pulsed for a
period of <Pulse Width>.
The trigger pulse must be a maximum width
to cause an output pulse. The output will pulse
if the trigger signal stays valid for less than
<Pulse Delay> time. The output starts on the
trailing edge of the trigger pulse and lasts for a
period of <Pulse Width>.