GARDASOFT TR-HT2 Series User Manual page 62

Led controller
Table of Contents

Advertisement

TT1 to enable the internal trigger using the period last set
TT1,p to enable the internal trigger and set the period.
Where:
p = trigger period in milliseconds.
Note :
The TT1 command does not disable external triggers.
Save the settings to memory
AW
This command saves the settings to non-volatile memory. If you
power cycle the TR-HT before sending the AW command, all
changes are lost and the unit returns to the values set before the last
AW command.
Clear configuration
CL
This command clears the configuration and lighting ratings, and
turns the output off. The results of any VL, RS, RW, RU, RT, RE, RP,
TT, and AW commands are cleared.
Show configuration
This command shows the configuration of the TR-HT. Type in:
ST
A typical reply to this command might be:
CH1,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,
RT 0.0us,IP1,FL0,CS0.000A,RA0.000A
CH2,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,
RT 0.0us,IP1,FL0,CS0.000A,RA0.000A
Where:
CH
channel number
mode: 0 = continuous, 1 = pulsed, 2 = switched
MD
S
brightness percentage setting:
DL
pulse delay
PU
pulse width
RT
retrigger delay
IP
input trigger (set using the RP command)
TR-HT2xx LED Controller - User Manual
First setting used in all modes
Second setting only used for selected mode
62