GARDASOFT TR-HT2 Series User Manual page 32

Led controller
Table of Contents

Advertisement

Mode
Mode
name
0
Set Low
(Off)
1
Set High
(On)
2
Pulse TT
(Ptt)
3
Pulse TE
(PtE)
4
Pulse ET
(PEt)
5
Pulse EE
(PEE)
6
Divide Trig
(Pd)
7
Divide Enc
(Enc)
8
Burst T
(bur)
9
(FrE)
TR-HT2xx LED Controller - User Manual
Operation
The output is set to off or logic 0. If the output
is inverted (flag O is set) then the output is
logic 1.
The output is set high (on) or logic 1. If the
output is inverted (flag O is set) then the
output is logic 0.
Pulsed output triggered by a digital input. The
delay and pulse width are set as fixed times.
Pulsed output triggered by a digital input. The
delay is a fixed time. The pulse width is a
number of encoder pulses.
Pulsed output triggered by a digital input. The
delay is a number of encoder pulses. The
pulse width is a fixed time.
Pulsed output triggered by a digital input. The
delay and pulse width are a number of
encoder pulses.
Pulse divider. Every <Pulse Delay> trigger
pulses, the output is pulsed for <Pulse Width>
time.
Pulsed output triggered by encoder pulses.
The output is pulsed for <Pulse Width>
encoder pulses with the pulses separated by
<Pulse Delay> encoder pulses. The Input and
Gate Input parameters are not used.
Burst output. When triggered, <Gate Input>
pulses are output. Each pulse is <Pulse
Width> long and the time between the end of
one pulse and the start of the next is given by
<Pulse Delay>. The maximum number of
pulses that can be output is 250. See Section
8.2.1, Burst mode.
Not used.