v = 0 to set the output to logic 0 (or logic 1 if the O flag is set)
1 to set the output to logic 1 (or logic 0 if the O flag is set)
Note1
: This is a temporary override which is cancelled the next time
the output is pulsed or if its configuration is changed.
Note 2:
If the O configuration flag is set for an output, that output is
inverted.
Show the state of an input
ZIi
Where i is the input channel (1 to 4).
This command returns
input is logic 1.
Override the state of an input
This command can be used to override the state of an input. The
override is cancelled as soon as an edge is detected on the input.
MIc,v
Where:
c
input channel (1 to 4)
= 0 to set the input to 'off'
v
= 1 to set the input to 'on'.
Show the state of an output
ZOc
Where c is the output channel (1 to 4).
This command returns
output is logic 1.
TR-HT2xx LED Controller - User Manual
if the input is logic 0, and
VL0
if the output is logic 0, and
VL0
68
if the
VL1
if the
VL1