Alpha ESS SMILE-T10-HV-INV User Manual
Alpha ESS SMILE-T10-HV-INV User Manual

Alpha ESS SMILE-T10-HV-INV User Manual

Energy storage system

Advertisement

User Manual
Energy Storage System (ESS)
SMILE-T10-HV
V04

Advertisement

Table of Contents
loading

Summary of Contents for Alpha ESS SMILE-T10-HV-INV

  • Page 1 User Manual Energy Storage System (ESS) SMILE-T10-HV...
  • Page 2: Imprint

    E-mail: info@alpha-ess.com Web: www.alpha-ess.com Add: JiuHua Road 888, High-Tech Industrial Development Zone 226300 Nantong City, Jiangsu Province Australia Alpha ESS Australia Pty. Ltd. Tel.: +61 1300 968 933 E-mail: australia@alpha-ess.com Web: www.alpha-ess.com.au Add: Unit 1, 2 Ralph Street Alexandria NSW 2015 Italy Alpha ESS Italy S.r.l.
  • Page 3: Copyright Statement

    Your Smart Energy Copyright Statement This manual is under the copyright of Alpha ESS Co., Ltd. with all rights reserved. Please keep the manual properly and operate in strict accordance with all safety and operating instructions in this manual. Please do not operate the system before read- ing through the manual.
  • Page 4: Table Of Contents

    5.3 WiFi Module Setting ................... 26 Commissioning ....................28 6.1 Checking Before Power-On................28 6.2 Configuring the safety standard ............... 30 6.3 Check the Running State .................. 31 6.4 Powering Off the Product .................. 32 ___________________________________________________________________ Alpha ESS Co., Ltd. Page 4 of 43...
  • Page 5 8.2 Packing the Product ................... 37 8.3 Disposing of the Product ................... 37 Specification ......................38 9.1 Datasheet of Hybrid Inverter SMILE-T10-HV-INV ..........38 9.2 Datasheet of Battery Pack SMILE-BAT-8.2PH ..........41 Appendix 1: Communication Connection Figure ............. 42 Appendix 2: Regional Application Standard ............43 ___________________________________________________________________ Alpha ESS Co., Ltd.
  • Page 6: Information On This Document

    1.1 Content and Structure of this Document This document is valid for product of SMILE-T10-HV system which include inverter SMILE-T10-HV-INV, battery pack SMILE-BAT-8.2PH. This document describes the mounting, installation, commissioning, configuration, operation, troubleshooting and decommissioning of the product as well as the opera- tion of the product user interface.
  • Page 7: Nomenclature

    Designation in this document SMILE-BAT-8.2PH (INDOOR) Battery Pack (INDOOR) SMILE-BAT-8.2PH (OUTDOOR) Battery Pack (OUTDOOR) SMILE-BAT-8.2PH-P (OUTDOOR) Battery Pack (OUTDOOR) SMILE-T10-HV-INV (INDOOR) Inverter (INDOOR) SMILE-T10-HV-INV (OUTDOOR ) Inverter (OUTDOOR) SMILE-T10-HV-INV with SMILE-BAT-8.2PH Product ___________________________________________________________________ Alpha ESS Co., Ltd. Page 7 of 43...
  • Page 8: Safety

    The enclosed documentation is an integral part of this product. Keep the documenta- tion in a convenient place for future reference and observe all instructions contained therein. The type label must remain permanently attached to the product. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 8 of 43...
  • Page 9: Safety Precaution For Battery Pack

    1. If fire occurs when charging batteries, if it is safe to do so, disconnect the battery pack circuit breaker to shut off the power to charge. 2. If the battery pack is not on fire yet, extinguish the fire before the battery pack catches fire. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 9 of 43...
  • Page 10 In water: Stay out of the water and don't touch anything if any part of the battery, inverter, or wiring is submerged. Do not use submerged battery again and contact the service engineer. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 10 of 43...
  • Page 11: Important Safety Instructions

    • Connect and ground the frame of the PV modules, the array frame and the electrically conductive surfaces so that there is continuous conduction. Observe the applicable local regulations. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 11 of 43...
  • Page 12 • If moisture has penetrated the battery pack (e.g. due to a damaged enclosure), do not install or operate the battery pack. • In case of contact with electrolyte, rinse the affected areas immediately with water and consult a doctor without delay. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 12 of 43...
  • Page 13 Damage due to cleaning agents The use of cleaning agents may cause damage to the product and its components. • Clean the product and all its components only with a cloth moistened with clear water. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 13 of 43...
  • Page 14: Symbols On The Label

    EU Equipment and Product Safety Act. CE marking The product complies with the requirements of the applicable EU directives. RCM (Regulatory Compliance Mark) The product complies with the requirements of the applicable Australian standards. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 14 of 43...
  • Page 15 Risk of electrolyte leakage CE marking The product complies with the requirements of the applicable EU directives. Refer to the instruction for operation Use eye protection Fire, naked light and smoking prohibited No nearing ___________________________________________________________________ Alpha ESS Co., Ltd. Page 15 of 43...
  • Page 16 Do not dispose of the battery pack together with the house- hold waste but in accordance with the locally applicable dis- posal regulations for batteries Recycling code Marking for transport of dangerous goods The product passes the certifications of the UN38.3 ___________________________________________________________________ Alpha ESS Co., Ltd. Page 16 of 43...
  • Page 17: Product Introduction And Application Scenarios

    The system is not operating. A fault of the system has occurred. FAULT No fault The battery pack works normally. Battery communication exists but is not BATTERY working normally Battery communication loss exists ___________________________________________________________________ Alpha ESS Co., Ltd. Page 17 of 43...
  • Page 18 4s Connected to the server but not logged in ,flash once every 2s Connected to the router,flash once every 1s Connected to the WiFi module, flash once every 500ms ___________________________________________________________________ Alpha ESS Co., Ltd. Page 18 of 43...
  • Page 19: Battery Pack Description

    Figure 2 Battery pack LED signals Four LED indicators are provided on the display panel. Different colors represent different states, green for SOC state, yellow for protection state, red for error state. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 19 of 43...
  • Page 20 All the LED indicators are always on. When the battery is being charged and the SOC is between 80% and 100%, the fourth line of the LED indicator will flash every 3s. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 20 of 43...
  • Page 21: Application Scenarios

    Your Smart Energy 3.3 Application Scenarios AlphaESS SMILE-T10-HV system (include SMILE-T10-HV-INV and SMILE-BAT- 8.2PH) can be applied in DC-coupled systems (mostly new installation), AC-coupled systems (mostly retrofit) and Hybrid-coupled systems (mostly retrofit, and PV capacity - increase), as the following scheme show: Figure 3 DC-coupled Storage System –...
  • Page 22: Storage

    4. Store the battery pack where it should be minimal dust and dirt in the area. 5. Handle batteries with caution to avoid damage. 6. The storage environment requirements are as follows: – Ambient temperature: -10~55°C; recommended storage temperature: 15~30°C ___________________________________________________________________ Alpha ESS Co., Ltd. Page 22 of 43...
  • Page 23 65~75% of the SOC. For example, they can be recharged every 6 months at least, and must be recharged to at least 50% of the SOC. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 23 of 43...
  • Page 24: Wifi Setting

    1.Android device users can download the APP through major Android application markets such as Google Play. 2.IOS device users can search for “AlphaESS” in AppStore and download the APP. Figure 6 AlphaESS-APP ___________________________________________________________________ Alpha ESS Co., Ltd. Page 24 of 43...
  • Page 25: Overview Of Functions For Installer Account

    Your Smart Energy 5.2 Overview of Functions for Installer Account ___________________________________________________________________ Alpha ESS Co., Ltd. Page 25 of 43...
  • Page 26: Wifi Module Setting

    Step 1: Open AlphaESS APP, click Step 2: After that please check the “Wi-Fi Configuration” button and whether your mobile phone has enter the WiFi configuration interface. connected to the system’s hotspot. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 26 of 43...
  • Page 27 Step 4: Select the WiFi of your home you are using, enter the password, complete the WiFi configuration and submit. If there is no network currently, you can click Jump over to skip the WiFi configuration step and directly set the system parameters. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 27 of 43...
  • Page 28: Commissioning

    Cable ties are secured evenly and no burr exists. The ground cable is connected correctly, se- Grounding curely, and reliably. Switch and breakers All breakers connecting to or on the product are status OFF. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 28 of 43...
  • Page 29 Unused power termi- Unused power terminals are blocked by water- nals tight caps. The mounting space is proper, and the mounting Mounting environment environment is clean and tidy, without foreign object. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 29 of 43...
  • Page 30: Configuring The Safety Standard

    • If you are not sure which safety standard is valid for your country or purpose, con- tact your grid operator for information on which safety standard is to be configured. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 30 of 43...
  • Page 31: Check The Running State

    NOTICE During commissioning, if the LED indictors on the display panel of the inverter or the battery pack show red, please refer to Section Error! Reference source not found. for troubleshooting. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 31 of 43...
  • Page 32: Powering Off The Product

    4. Switch off the PV switch between the PV string and the inverter if there is any. 5. Switch off the AC breaker between the inverter and the load. 6. Switch off the AC breaker between the inverter and the grid. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 32 of 43...
  • Page 33: Maintenance And Troubleshooting

    The heatsink and housing can get hot during operation. • During operation, do not touch any parts other than the cover of the inverter. • Wait approx. 30 minutes before cleaning until the heatsink has cooled down. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 33 of 43...
  • Page 34: Troubleshooting

    Restart inverter and ensure whether the fault is existing. 100057 Grid_disturbance2 1. Confirm whether Grid is distorted severely. 2.Check whether PV cable connection is reli- able. 100058 AFCI_check_protect 1.Check whether PV cable connection is reliable. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 34 of 43...
  • Page 35 Cell overvoltage See NOTE or call for service Cell under voltage Stop charging until this code is Low-temperature eliminated and Wait for the tem- charge perature to rise. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 35 of 43...
  • Page 36 When the protection code NO. 9 appears, please quickly push the Power button 5 times in 10 seconds to force the BMS startup the MOSFET of discharging. Thus the open-circuit voltage of the battery will be detected by the inverter and get charged. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 36 of 43...
  • Page 37: Remove & Return

    Dispose of the packaging and replaced parts according to the rules at the installation site where the device is installed. Do not dispose the inverter and the battery pack with normal domestic waste. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 37 of 43...
  • Page 38: Specification

    Your Smart Energy Specification 9.1 Datasheet of Hybrid Inverter SMILE-T10-HV-INV Item SMILE-T10-HV-INV (OUTDOOR) SMILE-T10-HV-INV (INDOOR) Input DC (PV side) Recommended max. PV power 16000 W Max. PV input voltage 1000 V Rated voltage 600 V Start-up voltage 160 V MPPT voltage range 200 ~ 850 V Max.
  • Page 39 Battery reverse protection Integrated PV switch Integrated Battery breaker Integrated General data Dimensions(W*H*D) 580*606*230 mm Weight 30 kg Topology Transformerless Operation temperature range -25 ~ +60 °C Ingress protection IP65 IP21 ___________________________________________________________________ Alpha ESS Co., Ltd. Page 39 of 43...
  • Page 40 IEC 60068, IEC 61683, EN 50530, MEA, PEA IEC62040-1, IEC62109-1/-2.AS3100, Safety/EMC standard NB/T 32004, EN61000-6-2, EN61000-6-3 Features DC connection MC4 connector AC connection Terminal block Communication LAN, WiFi (optional) Warranty 5 years standard ___________________________________________________________________ Alpha ESS Co., Ltd. Page 40 of 43...
  • Page 41: Datasheet Of Battery Pack Smile-Bat-8.2Ph

    System voltage, current, cell voltage, Monitoring Parameters cell temperature, PCBA temperature Communication CAN and RS485 compatible Safety IEC62619(Cell), IEC 62619(Pack) Transportation UN38.3 * During low temperature and high temperature, the battery performance will be derating. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 41 of 43...
  • Page 42: Appendix 1: Communication Connection Figure

    ∙ If the extra PV inverter is not used, the system is suitable for DC mode. ∙ If you have the extra PV inverter, the system is suitable for AC or Hybrid mode. ___________________________________________________________________ Alpha ESS Co., Ltd. Page 42 of 43...
  • Page 43: Appendix 2: Regional Application Standard

    Choose the correspond Regional Application Standard, the power quality modes Volt- var and Volt-Watt will run automatically (only for regions with AS/NZW 4777.2 safety regulations). Regional application Standard Electric Company Australia A Australia B Australia C New Zealand Vector Vector ___________________________________________________________________ Alpha ESS Co., Ltd. Page 43 of 43...

Table of Contents