ETC Installation Guide
Pro One-Cell
Wire and Terminal Specifications
Terminal/Connector
D1 power input
line/neutral/ground
D1 HOand D2 power input
line/neutral
D4 maintained power input
line/neutral
D4 emergency drivers
sense power input
line/neutral/ground
Power Input
ground
DMX In/Thru
RJ45 Connectors
Outputs for all D1, D2, and
D4 Series Drivers with Molex
connectors
Outputs for D4 drivers with
terminals
Note:
D2 Series drivers is 15 m (49 ft).
Maximum supported wire length between any load and a D4 Series driver is 10 m (33 ft).
Mounting the Driver
Depending on your installation, you might want to surface-mount the driver. Any ArcSystem
standalone driver can be surface-mounted to any surface capable of supporting its weight using the
four holes located on the back side of the enclosure. Contact ETC for custom mounting bracket
options.
1.
Remove the two screws on the cover of the driver and set them aside.
2.
Remove the driver cover. The cover is tethered to the backbox. Be careful when handling.
Note:
and has wiring that runs to the driver board in the back panel of the driver. Be careful when
handling. It may help to nest the back panel of the driver inside the cover as shown in
Wiring the Driver and Luminaire on
3.
Using four #10 screws, mount the back panel to the mounting surface.
4.
Attach flexible conduit to the driver. There are four conduit knockouts available.
5.
Install Romex or nonmetallic screw-clamp conduit connectors to output knockouts, as needed.
Pro One-Cell
Conduit
Entry
½ in
Up to 6 mm
conduit
½ in
0.5–10 mm
conduit
½ in
0.2–2.5 mm
conduit
½ in
2.5–10 mm
conduit
Cat5e (or better) minimum 0.2 mm
½ in
(24 AWG) conductors terminated to
conduit
T568B standard
½ in
Follow Class 2 wiring methods.
conduit
0.2–2.5 mm
½ in
provided two-terminal connectors.
conduit
Follow Class 1 wiring methods.
Maximum supported wire length between One-Cell luminaires and D1 Series and
If you are installing a D1 High Output driver, the power supply is inside the cover
Wire Range/Specifications
2
(10 AWG) solid or stranded
2
(22–6 AWG)
2
(24–14 AWG)
2
(6–14 AWG)
2
(26–14 AWG) using the
page 12.
Page 9 of 29
Strip
Torque Rating
Length
7 mm
0.8 Nm
(1/4 in)
(7 in-lb)
7 mm
0.5 Nm
(1/4 in)
(4.4 in-lb)
6.5 mm
0.5–0.6 Nm
(1/4 in)
(4.4–5.3 in-lb)
10 mm
4.0 Nm
(3/8 in)
(35 in-lb)
2
N/A
N/A
6 mm
0.4–0.5 Nm
(1/4 in)
(3.5–4.4 in-lb)