Chapter 4
Reroute the existing load sense hose to the SmarTrax valve and connect it to the 'LSPV' port.
5.
Note:
The supplied 45° elbow and 90° elbow fittings (P/N 333-0012-027 or 333-0012-042) may be used
to simplify connection to the SmarTrax valve and help with hose routing. Use these fittings to help
route hoses away from wear areas or snagging during normal equipment operation.
Connect the supplied hose (P/N 214-1000-665) to the 'LS Steer' port on the SmarTrax valve and route this
6.
hose to the open load sense port on the steering orbitrol.
SmarTrax Hydraulic Valve
FIGURE 4.
Once these hoses are connected, double check to make sure that all hydraulic hose and fitting connections
7.
are tight.
Pressure and Tank, Left and Right Hoses
Connect a supplied tee fitting (P/N 333-0012-028) to each of the ports on the steering orbitrol.
1.
Reconnect the existing hydraulic hoses to the installed tee fittings. Be sure to reconnect the hoses to the
2.
correct ports as previously labeled.
Steering Orbitrol Ports
FIGURE 5.
Tank
Pressure
Connect the supplied 90° elbow fittings (P/N 333-0012-067) to each of the tee fittings.
3.
14