Powering Off The Chassis - Broadcom Brocade DCX 8510-4 Backbone Hardware Installation Manual

Table of Contents

Advertisement

53-1002177-19 Hardware Installation Guide

Powering off the chassis

Perform the following steps to power off the chassis.
1. Shut down the chassis using the
switch::admin> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y
HA is disabled
Stopping blade 1
Shutting down the blade....
Stopping blade 2
Shutting down the blade....
Stopping blade 8
Shutting down the blade....
Broadcast message from root (pts/1) Tue Aug 23 14:23:06 2010...
The system is going down for system halt NOW !!
2. Power off the chassis by flipping the AC power switches on the power supplies to O (LEDs inside AC power switches
should turn off). To maintain the ground connections, leave power cords connected to the power supplies and to the
electrical outlets.