53-1002177-19 Hardware Installation Guide
INIT: Switching to runlevel: 6
INIT: Sending processes the TERM signal DCX_124:admin> HAMu Heartbeat down, stop FSS
Unmounting all ##exiting due to signal: 9, pending signals: 0x20000, 0x0
ilesystems.
Please stand by while rebooting the system...
Restarting system.
The system is coming up, please wait...
.
.
.
Fri Jun 18 14:53:13 2010: Doing firmwarecommit now.
Please wait ...
Fri Jun 18 14:55:27 2010: Firmware commit completes successfully.
Validating the filesystem ...
Fri Jun 18 22:36:05 2010: Doing firmwarecommit now.
Please wait ...
Fri Jun 18 22:36:48 2010: Firmware commit completes successfully.
2010/06/18-14:56:50, [SULB-1004], 908, SLOT 7 | CHASSIS, INFO, Brocade_DCX, Firmwarecommit has completed.
2010/06/18-14:56:50, [SULB-1036], 909, SLOT 7 | CHASSIS, INFO, Brocade_DCX, The new Version: Fabric OS
v6.3.0c
2010/06/18-14:56:50, [SULB-1002], 910, SLOT 7 | CHASSIS, INFO, Brocade_DCX, Firmwaredownload command has
completed successfully.
NOTE
The time stamp on the co-CPU may not be in sync with the main CPU on the blade. This is not a cause for
concern.
8. Log back in to the standby CP blade and enter
successful commit. This may take 10 minutes.
9. If you are upgrading through several levels of the Fabric OS, repeat step 5 through step 8 as often as necessary
based on the path outlined in the preceding table. Otherwise, proceed to step 10.
10. Log out of the standby CP blade and log in to the active CP blade.
11. Proceed to the procedures to "Completing the replacement."
Downloading Firmware from FTP Server
For this task, determine the correct sequence of upgrading firmware versions to reach your target version.
Complete the following steps to download the firmware from an FTP server to the replacement blade.
1. Log on to the standby CP blade as admin . If you need to know the IP address of the standby blade, run ipaddrshow
.
You should remain logged on to the active CP blade in order to monitor it.
2. Run firmwareDownload -s to download the firmware to the replacement (standby) CP blade. The -s option
also disables the autoreboot, so you will have to manually issue a reboot after the download finishes to initiate a
firmwarecommit . Enter all requested information (use default values).
3. When the download process finishes, run firmwareDownloadStatus to verify that the firmware has been updated.
The command displays a running account of the progress of the firmwareDownload command (if it is still running)
until the command has completed. The final message is similar to the following and will appear with a date and time
stamp.
Broadcom
firmwareDownloadStatus
Brocade DCX 8510-4 Backbone Hardware Installation Guide
on the standby CP blade to validate a
53-1002177-19
116