Chain Lubrication (First Use); Filling The Chain Oil Reservoir; First Forced Lubrication Cycle - pellenc SELION M12 Operating Instructions Manual

Hide thumbs Also See for SELION M12:
Table of Contents

Advertisement

4.3. CHAIN LUBRICATION (FIRST USE)

4.3.1. FILLING THE CHAIN OIL RESERVOIR

Before the first use, it is essential to fill the chain oil reser-
voir with the specific chain and guide oil (Ref.: 116688)
1.
Unscrew the guide and chain oil reservoir cap (9)
2.
Carefully pour the guide and chain oil into the reser-
voir.
3.
Tighten the chain oil tank cap (9)
Important
Check the oil level every hour and top it up if nec-
essary.
Note
PELLENC recommends using a biodegradable chain oil that complies with the RAL-UZ-48 standard (ref.
116688, otherwise any oil that complies with the RAL-UZ-48 standard)
Consumables sold separately.
Warning
Never use dirty or used oil.

4.3.2. FIRST FORCED LUBRICATION CYCLE

The forced lubrication cycle distributes the oil from the
reservoir to the different components. It is imperative to
carry out this forced lubrication cycle before first use of
the Chainsaw Selion M12.
1.
Press and hold the triggers (3) and (2).
2.
Set the battery switch to "1".
3.
An automatic cycle starts which sends oil from the
reservoir to the chain guide.
a.
short beep every 20 seconds during the cycle.
b.
3 beeps to validate the end of the cycle.
4.
Release the triggers when you hear the first beep.
Note
Note: the chain does not rotate during the forced lubrication cycle phase.