pellenc SELION M12 Translate Of The Original Manual

pellenc SELION M12 Translate Of The Original Manual

Hide thumbs Also See for SELION M12:
Table of Contents

Advertisement

Quick Links

ENG
.
Translate of the
original manual
CHAINSAW
SELION M12
51_149238-C
Operating instructions
06/2021
READ THE USER GUIDE CAREFULLY BEFORE USE

Advertisement

Table of Contents
loading

Summary of Contents for pellenc SELION M12

  • Page 1 Translate of the original manual CHAINSAW SELION M12 51_149238-C Operating instructions 06/2021 READ THE USER GUIDE CAREFULLY BEFORE USE...
  • Page 3: Table Of Contents

    2.2.7. TOOL’S END OF LIFE MANAGEMENT ....................2.3. CHAIN SAW SAFETY WARNINGS ....................2.4. CAUSES AND OPERATOR PREVENTION OF KICKBACK ............2.5. SAFETY MEASURES RELATED TO THE USE OF THE PELLENC BATTERY AND CHARG- ................................2.6. PERSONAL PROTECTION EQUIPMENT ..................2.7. SAFETY SIGNAGE ........................
  • Page 4 CHAINSAW SELION M12 51_149238-C 4.9.3. ULIB 700 / OLIVION+ BATTERY ...................... 4.10. DISCONNECTING PELLENC BATTERIES FROM THE TOOL ..........4.10.1. ULIB 250 BATTERY ........................4.10.2. ULIB 750 / ALPHA 260 / ALPHA 520 BATTERIES ................4.10.3. ULIB 700 / OLIVION+ BATTERY ....................
  • Page 5 CHAINSAW SELION M12 51_149238-C 10.1. GENERAL WARRANTIES ......................10.1.1. STATUTORY WARRANTY ......................10.1.2. COMMERCIAL WARRANTYPELLENC .................... 10.1.3. PAID AFTER-SALES SERVICE ...................... 11. COMPLIANCE STATEMENTS ................... 47 11.1. "EC" DECLARATION OF CONFORMITY: SELION M ...............
  • Page 6: Introduction

    51_149238-C 1. INTRODUCTION Dear Customer, Thank you for purchasing your Chainsaw Selion M12. Correctly used and maintained, this tool will give a satisfactory performance for many years. Warning Your device contains numerous recoverable or recyclable materials. Return it to your dealer or, failing this, to an approved servicing centre to be treated.
  • Page 7: Safety

    • The Chainsaw Selion M12 must be used at ground level or from a suitable platform that is completely stable and secure. • When is use the Chainsaw Selion M12 should be held in both hands, right hand on the trigger handle and left hand on the top handle.
  • Page 8: Personal Safety

    CHAINSAW SELION M12 51_149238-C When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. If operating a power tool in a damp location is unavoidable, use a residual current device (RCD) pro- tected supply.
  • Page 9: Service

    2.2.7. TOOL’S END OF LIFE MANAGEMENT When the tool reaches the end of its life, PELLENC keeps the end of life sheet of the equipment at disposal. The end of life sheet provides instructions for safely removing components.
  • Page 10: Safety Measures Related To The Use Of The Pellenc Battery And Charger

    Decreas- ing the depth gauge height can lead to increased kickback. 2.5. SAFETY MEASURES RELATED TO THE USE OF THE PELLENC BATTERY AND CHARGER Refer to the instructions supplied with the PELLENC battery and charger. 2.6. PERSONAL PROTECTION EQUIPMENT...
  • Page 11: Safety Signage

    Do not expose to rain 2.8. RESIDUAL RISKS Even when using the Chainsaw Selion M12 as intended, there is always a degree of unavoidable residual risk. The following potential risks may apply: • Risk of cuts due to contact with exposed saw teeth of the Chainsaw Selion M12 •...
  • Page 12: Description And Technical Characteristics

    CHAINSAW SELION M12 51_149238-C 3. DESCRIPTION AND TECHNICAL CHARACTERISTICS 3.1. DESCRIPTION Handle Oil tank cap Operating trigger 10. Tool power cable Safety trigger 11. Telescopic tightening wrench Right hand guard 12. “On” light Chain casing 13. Arm band Saw chain 14.
  • Page 13: Technical Features

    CHAINSAW SELION M12 51_149238-C 3.2. TECHNICAL FEATURES 3.2.1. GENERAL CHARACTERISTICS Selion M12 Battery life Depending on the use and type of battery Chain oil tank capacity 7 cl Useful cutting length / chain guide See the chart Section 3.2.2, “Chains and chain guides compatibility”...
  • Page 14: Vibration Levels

    CHAINSAW SELION M12 51_149238-C 3.2.5. VIBRATION LEVELS Determination of the vibration levels is based on the operating conditions at the nominal maximum speed. Vibration level according to 6.2 of EN 60745-1 and EN 60745-2-13 Vibration emission value (measurement uncertainty K = 1.5 m / s²)
  • Page 15: Commissioning

    Caution Always disconnect the tool battery before starting tool maintenance. • Use products recommended by PELLENC. • In the event of any problem, consult an authorised PELLENC distributor. 4.3. ASSEMBLY OF THE CHAIN AND CHAIN GUIDE (1ST USE) Note Refer to the numbering of the parts in the illustration Section 3.1, “Description”.
  • Page 16: Chain Guide Functions

    CHAINSAW SELION M12 51_149238-C The chain guide and the chain are delivered unassem- bled. Assemble the chain guide and the chain. Position the chain guide (7) in its place. Push the guide (7) towards the sprocket to engage the lock.
  • Page 17: Automatic Chain Tensioning (First Use)

    CHAINSAW SELION M12 51_149238-C 4.3.1.2. THE CARVING CHAIN GUIDE The carving chain guide has a very narrow profile that allows for easier access to difficult areas, while incurring very little kickback. It is used for more precise cuts such as: •...
  • Page 18 CHAINSAW SELION M12 51_149238-C Tighten the chain guard lock nut (8) correctly using the telescopic wrench (11), the chain guide (7) then moves forward and automatically tensions the chain (6). Re-position the handle of the telescopic wrench (11) on its holding magnet.
  • Page 19: Chain Lubrication (First Use)

    Check the oil level every hour and top it up if nec- essary. Note PELLENC recommends using a biodegradable chain oil that complies with the RAL-UZ-48 standard (ref. 116688, otherwise any oil that complies with the RAL-UZ-48 standard) Consumables sold separately.
  • Page 20: Running-In (Before First Use)

    CHAINSAW SELION M12 51_149238-C Warning Carry out a forced lubrication cycle at the start of each season in order to check the chain lubricating function. Carry out forced lubrication whenever necessary. 4.6. RUNNING-IN (BEFORE FIRST USE) Warning Before the first use, it is imperative to run-in the chain guide and chain.
  • Page 21: Fitting The Battery On The Harness

    After mounting, the battery must be solidly attached and secured on your harness. If this is not the case then the mounting needs to be re-checked. 4.9. CONNECTING PELLENC BATTERIES TO THE TOOL Important Always check the remaining battery-life before use. If necessary, recharge the battery using the charger.
  • Page 22: Disconnecting Pellenc Batteries From The Tool

    To prolong the life of the connectors, it is advisable to protect them when they are disconnected. Avoid leaving the connectors in contact with abrasive or dirty surfaces, or subjecting them to major impacts (falls). For more information on PELLENC batteries see the battery instructions.
  • Page 23: Ulib 250 Battery

    CHAINSAW SELION M12 51_149238-C 4.10.1. ULIB 250 BATTERY Unscrew the connector safety ring to release the power cord (10). 4.10.2. ULIB 750 / ALPHA 260 / ALPHA 520 BATTERIES Disconnect the tool's power cord from the extension cord. 4.10.3. ULIB 700 / OLIVION+ BATTERY Unscrew the connector safety ring to release the power cord (10).
  • Page 24: Usage

    CHAINSAW SELION M12 51_149238-C 5. USAGE 5.1. USAGE SITUATION Do not use the chainsaw to prune trees one-handed when in an unstable work position. It is preferable to use a hand saw when cutting small diameter wood at the ends of branches.
  • Page 25: Ulib 750 Battery

    CHAINSAW SELION M12 51_149238-C 5.3.2. ULIB 750 BATTERY Press one of the 2 battery On/Off buttons. 5.3.3. ALPHA 260 / ALPHA 520 BATTERY Press the battery On/Off button. 5.3.4. ULIB 700 / OLIVION+ BATTERY • Switching on: put the switch in the "0" position.
  • Page 26: Holding The Tool

    Always start the motor before bringing the chainsaw into contact with the wood. Remove the chain guide protector. Set the Pellenc tool battery On/Off switch to the On position “I”. From the moment the indicator light (12) comes on, the tool is energized and ready to operate.
  • Page 27: Electronic

    CHAINSAW SELION M12 51_149238-C Allow the chainsaw to cut without pressing excessively. 5.6. ELECTRONIC Your chainsaw is fitted with an impact detection system In the event of impact (kickback) your chainsaw will stop immediately. Warning Make sure the chain is not in contact with wood before restarting the chain- saw.
  • Page 28: Service

    Always disconnect the tool battery before starting tool maintenance. • Use products recommended by PELLENC. • In the event of any problem, consult an authorised PELLENC distributor. 6.2. THE FOUR BASIC RULES • Rule No. 1: The chain must be correctly tensioned.
  • Page 29: Maintenance Frequency

    CHAINSAW SELION M12 51_149238-C • Rule No. 3: The chain must be sharpened. A properly sharpened chain improves cutting perfor- mance and reduces wear. Refer to procedure Section 6.7, “Sharpening the chain” • Rule No. 4: The depth limiters must be correctly adjusted.
  • Page 30: Replacing The Chain And The Chain Guide

    CHAINSAW SELION M12 51_149238-C Warning Overhaul the chainsaw every 200 hours or at least once a year. Always make sure the tool is clean and its battery is charged before storing it. 6.4. REPLACING THE CHAIN AND THE CHAIN GUIDE Important Do not use any chain guides or chains other than those recommended.
  • Page 31 CHAINSAW SELION M12 51_149238-C...
  • Page 32: Automatic Chain Tensioning

    CHAINSAW SELION M12 51_149238-C Caution Never use a chain or a guide other than those specified by PELLENC, otherwise there is a risk of personal injury. 6.5. AUTOMATIC CHAIN TENSIONING Important Check and adjust the tension of the chain: • prior to each use.
  • Page 33 CHAINSAW SELION M12 51_149238-C Tighten the chain guard lock nut (8) correctly using the telescopic wrench (11), the chain guide (7) then moves forward and automatically tensions the chain (6). Re-position the handle of the telescopic wrench (11) on its holding magnet.
  • Page 34: Chain Lubrication

    Check the oil level every hour and top it up if nec- essary. Note PELLENC recommends using a biodegradable chain oil that complies with the RAL-UZ-48 standard (ref. 116688, otherwise any oil that complies with the RAL-UZ-48 standard) Consumables sold separately.
  • Page 35: Sharpening The Chain

    CHAINSAW SELION M12 51_149238-C 6.7. SHARPENING THE CHAIN Set the battery switch to "0" and disconnect the con- nector. As shown on the diagram, place a file holder on the top platen and the depth limiter of the cutter. Caution...
  • Page 36: Adjusting The Depth Limiters

    CHAINSAW SELION M12 51_149238-C If the side platen or the top platen is damaged, file until this part is removed. All the gouges must be same length. Important After sharpening the cutters, check the depth limiters again. To do this follow the procedure Section 6.8, “Adjusting the depth limiters”.
  • Page 37 CHAINSAW SELION M12 51_149238-C Use a depth gage corresponding to the type of chain to be sharpened. Place the depth gauge on the gouge. If the depth limiter goes beyond, file it to the level of the depth gage using a flat file.
  • Page 38: Checking And Replacing The Sprocket

    CHAINSAW SELION M12 51_149238-C After reducing the height of the depth limiters, round off the angle to maintain the original shape of the depth limiters. Note On chains with drive links equipped with anti-kick- back guards, it may be necessary to take the chain out of the guide in order to file the depth limiters correctly.
  • Page 39: Greasing The Anti-Kickback Chain Guide

    CHAINSAW SELION M12 51_149238-C 6.11. GREASING THE ANTI-KICKBACK CHAIN GUIDE Lubricate the chain wheel nose sprocket (7) every day using a grease gun (ref.: 68518) through the grease hole (see diagram opposite). Note Consumables sold separately. 6.12. CLEANING THE TOOL Keep the tool clean by cleaning it frequently using a damp cloth and compressed air.
  • Page 40: Incidents And Troubleshooting

    PELLENC SAS. The Chainsaw Selion M12 will not start Check the following points: • Check that the Chainsaw Selion M12 is correctly con- nected to the battery. • Check the battery charge level. If none of these procedures succeeds in resolving the problem, contact a certified distributor or after-sales ser- vice PELLENC SAS.
  • Page 41: Storage And Transport

    CHAINSAW SELION M12 51_149238-C 8. STORAGE AND TRANSPORT 8.1. CHAIN PROTECTION Put on the chain protector (17) whenever transporting, handling and storing the tool. Warning Never transport the chainsaw without its protective cover. 8.2. OFF-SEASON STORAGE • Always clean the tool before storing it.
  • Page 42: Accessories And Consumables

    Round file (box of 12) 68521 Flat file (box of 12) 68522 Round file (pack of 3) 68611 9.2. OPTIONAL ACCESSORIES Name reference PELLENC ULIB 250 battery pack 57107 Name reference Comfort harness 57183 Lightweight harness 57257 PELLENC ULIB 750 battery...
  • Page 43: Consumables

    CHAINSAW SELION M12 51_149238-C Name reference Alpha harness 57194 PELLENC ALPHA 260 battery 57192 PELLENC ALPHA 520 battery 57193 Quick connect adapter 57262 Extension cord 57248 Name reference Olivion+ battery pack 57173 9.3. CONSUMABLES References: 5L can of organic oil...
  • Page 44: Warranties

    The warranty is fully integral to the product sold by PELLENC. 10.1.2.1.2. SPARE PARTS The commercial warranty also covers original PELLENCspare parts, excluding labour and to the exclusion of certain...
  • Page 45: Paid After-Sales Service

    PELLENC Products are guaranteed under the commercial warranty as from delivery to the customer for a period of two (2) years for products connected to a PELLENC battery, and for a period of one (1) year for other PELLENC products.
  • Page 46 Paid after-sales service also covers original PELLENC spare parts, excluding labour and outside the legal and commercial warranty period. In case of replacement of original PELLENC spare parts in the context of after-sales service, said latter are covered by a warranty of one year as from the installation date.
  • Page 47: Compliance Statements

    11.1. "EC" DECLARATION OF CONFORMITY: SELION M MANUFACTURER PELLENC ADDRESS Quartier Notre-Dame - 84120 Pertuis (France) ENTITY AUTHORIZED TO COMPILE THE TECHNICAL FILE PELLENC ADDRESS Quartier Notre-Dame - 84120 Pertuis (France) We hereby declare that the machine referred to below as: GENERIC DENOMINATION...
  • Page 51 PELLENC Quartier Notre Dame - 84120 Pertuis (France)

Table of Contents