The following items can be set in the "Alert" dialog box.
item
AMS
Set the actions to be taken at the next stage for
an unacknowledged alert.
Refer to "3.7.2 Setting up alert processing".
3.7.2
Setting up alert processing
When [AMS] is selected in the Classification pane, the "AMS" dialog is displayed on the Edit pane.
In this dialog, the time to activate the action at the next stage when acknowledge is not performed for
an alert can be set up.
Item
Reactivation of
Set, within the range from 0 second to 60 seconds, the time
Silenced Alert
required to reactivate the alert sound that was silenced temporarily
if the alert is not unacknowledged.
This setting is valid when alert of equipment that is set or legacy
alert. BAM standard compliant equipment is invalid.
Transfer to
When a BNWAS (Bridge Navigational Watch Alarm System) is
BNWAS
connected, specify the time to transfer an unacknowledged alert to
the BNWAS in a range between 0 and 30 seconds.
This setting is valid when alert of equipment that is set or legacy
alert. BAM standard compliant equipment is invalid.
Section 3 Bridge Alert Management (BAM)
contents
Contents
3-40
Function restriction
None
Remarks
Default: 30 s
Default: 30 s