Power Requirements - Spectra Logic Spectra 2K Library User Manual

Fibre channel serverless backup ndmp iscsi
Table of Contents

Advertisement

Power Requirements

Power requirements for the Spectra 2K library are summarized in the table below:
Source
Input Voltage
Input Power
Input Frequency
Fuses
a.
The fuse replacement procedure is explained in Replacing the Fuses on page 69.
Power Cable
The power cable included with the Spectra 2K library is a standard, three-conductor,
18-AWG power cord safe for 120-volt use in the United States and Canada. The cable
has a molded NEMA 5-15P male connector to plug in the wall and a molded IEC type
CEE-22 female connector to plug in the library.
Note:
To use the library outside of the United States or Canada, the
power cord must meet the specifications for that country.
220-Volt AC Power Cord for Use in North America
The criteria for a U.S. and Canadian 220-volt AC power cord for the Spectra 2K library
are as follows:
•Power cord must have a molded NEMA 6-15P attachment plug on one end.
•Power cord must have a molded IEC type CEE-22 female connector to connect to the
library.
•Cordage must be SJT type, three-conductor, 18-AWG minimum.
•Power cord must comply with local electrical code.
Appendix A. Specifications
Requirements
100-240-volt AC; 2 A maximum
90 watts minimum, 120 watts maximum
50/60 Hz
2 each 1/4" x 1-1/4" or 5x20 mm (3AG) 250-volt, 2A slow fuses
83