Table Of User Parameters And Functions - Riello NEXPOLAR 004 ME Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

NexPolar
Table of functions and user parameters
Function
Param-
eter
Mode
1
Homeantifreeze
2
Ambient antifreeze tem-
3
perature
Set point adjustment
4
frequency reduction
5
mode
Frequency reduction
6
Room mode
7 Lock The control panel displays these parameters
Room control set point
8 Lock This code is the control room set point determined by pressing the
Room set point
9 Lock This is the room air temperature read by the thermostat sensor
Relative humidity value
10 Lock This is the relative humidity value from the thermostat sensor
from the sensor
Outdoor temperature
11 Lock Outdoor Temperature measured by the sensor
Outdoor temperature -
12 Lock Outdoor temperature read by the GMC board
GMC
Room sensor tempera-
13
ture adjustment
Day period
14
"At home" temperature
15
in heating mode
"At home" temperature
16
in cooling mode
"Night" temperature in
17
heating mode
"Night" temperature in
18
cooling mode
"Away from Home"
19
temperature in heating
mode
"Away from Home"
20
temperature in cooling
mode
Room set point
21 Lock Room set point
Last alarm code
22 Lock Shows the last alarm code
Alarms log
23 Lock Shows the 4 most recent error codes
In case of parameters which are read-only and cannot be edited by user, key pad lock ( Lock) icon is displayed on the screen.
The list of Read-only parameters is given below: 7, 8, 9, 10, 11, 12, 21, 22 and 23
Description
This parameter allows you to select the mode
0. Off
2. Cooling
3. Heating
This parameter enables the ambient antifreeze option when the
system is off:
1. NO. Disabled
2. YES. Enabled
This code allows you to select the temperature threshold below
which the ambient (0/+ 2 °C hysteresis) antifreeze starts
Changing the water set point on the basis of the temperature
taken by the thermostat
This code provides the information whether the mode is activated:
Night/Reduction of the frequency
1. Not active
2. Active
Value of the compressor's frequency reduction in %
1. At home
2. Night
3. Away from home
home, night, away buttons
Correction of the temperature read to correct errors due to the
position of the thermostat.
This parameter specifi es the number of periods per day that should
be activated for the timing programme:
2
4
6
AT HOME set point temperature in heating mode
AT HOME set point temperature in cooling mode
NIGHT set point temperature in heating mode
NIGHT set point temperature in cooling mode
AWAY FROM HOME set point temperature in heating mode
AWAY FROM HOME set point temperature in cooling mode
52
Icon
Value range
Min
Max
Current mode
-
-
antifreeze:
1
2
°C
6°C
12°C
°C
-5°C
+5°C
1
2
50% 100%
Arrow depending
1
3
on the Touch 'N
Go selected
°C
12°C
38°C
°C
-20°C 50°C
%
0
100
°C
-30°C 90°C
°C
-20°C 65°C
°C
-5°C
5°C
2
6
°C and the At
12°C
38°C
Home arrow
°C and the At
12°C
38°C
Home arrow
°C and the
12°C
38°C
night arrow
°C and the
12°C
38°C
night arrow
°C and the away
12°C
38°C
from home arrow
°C and the away
12°C
38°C
from home arrow
°C
12°C
38°C
-
-
-
-
Set
value
0
1
6°C
0°C
1
100%
1
20°C
0°C
4
20°C
24°C
18°C
26°C
15°C
28°C
20°C

Hide quick links: