DCR-PC101/PC101E
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENTS
Before perform the viewfinder system adjustments, check the data
of page: 0, address: 10 is "00".
If not, select page: 0, address: 10, and set the data "00".
Note 1: Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 2: Perform the following data setting before the viewfinder
system adjustments.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1006 of the VC-284 board.
Connect the Measuring Instruments via the CPC-6 flexible jig (J-
6082-370-B) and CPC-6 terminal board jig (J-6082-371-A).
The following table shown the Pin No. and signal name of CN1006.
Pin No. Signal Name
1
FLASH_UNREG
3
EVF_LED_DA
5
EVF_VCO
7
MD2
9
XINIT
11
DRUM_ON
13
REC_CRRT1
15
REG_GND
17
SWP
19
GND
CN1006
2
1
20
19
Pin No. Signal Name
2
D_2.8V
4
EVF_VG
6
GND
8
XCS_MC_FLASH
10
XCS_ST_IMAGE_IC
12
FRRV
14
REC_CRRT0
16
HI_XRESET
18
RF_IN
20
RF_MON
Screw
CPC lid
Fig. 5-1-14

1. VCO Adjustment (VC-284 board)

Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: NTSC model: DCR-PC101
PAL model: DCR-PC101E
Adjusting method:
Order Page Address Data
1
0
01
2
C
51
3
C
51
4
C
51
5
6
7
8
C
52
9
0
01
Note 3: Refer to table 5-4-1. "Hexadecimal-decimal conversion
table"
Note 4: If D
' > 255, then D
52
If D
' < 0, then D
52
5-34
CAMERA
Not required
Pin 5 of CN1006 (EVF_VCO)
Frequency counter
C
51, 52
f = 15734 ± 30 Hz (NTSC)
f = 15625 ± 30 Hz (PAL)
Procedure
01
Change the data and set the
frequency (f) to the specified
value.
Press PAUSE button.
Read the data and this data is
named D
.
51
Convert D
to decimal
51
notation, and obtain D
(Note 3)
Calculate D
' using
52
following equations.
(decimal calculation)
D
' = D
' + 25 (NTSC model)
52
51
D
' = D
' – 25 (PAL model)
52
51
Convert D
' to a hexadeci-
52
mal number, and obtain D
(Note 3, 4)
D
Press PAUSE button.
52
00
= FF (NTSC model)
52
= 00 (PAL model)
52
'.
51
.
52