Environmental specifications

Storage shelf technical specifications (continued)
Table 3-2
Parameter
Power supplies
Power consumption
Power parameters
Inherent availability of the system
Mean Time to Repair (MTTR)
See
"Environmental specifications"
The following table lists the requirements for the NetBackup appliance and the
storage devices.
Environmental requirements
Table 3-3
Component
Operating temperature
Storage temperature
Transportation temperature
Temperature gradient
Operating humidity
Operating altitude
Technical specifications, standards, and compliance information
Description
Dual 580W, 100 - 240 VAC auto ranging, 50-60 Hz,
hot swappable power supplies
326 W at 110 V
372 W at 220 V
AC voltage range:
110 V at 2.972 A
220 V at 1.756 A
AC frequency range: 50 Hz to 60 Hz
≥ 99.95%
< 1 hour
on page 32.
Requirement
10°C to 35°C (50°F to 95°F)
-40°C to 70°C (-40°F to 158°F)
-40°C to 70°C (-40°F to 158°F)
10°C/hour
10%RH to 85%RH
-30 meters to 3,000 meters
In altitudes from -60 meters to +1,800 meters, the ambient
temperature ranges from 5°C to 35°C. When the altitude
ranges from 1,800 meters to 3,000 meters, the environment
temperature decreases by 0.6°C when the altitude increases
by 100 meters.
Environmental specifications