18
Setting the Egg Timer Feature (One time schedule)
The "Egg Timer" feature lets you manually switch on equipment and program the system to automatically
switch off after a specified time. You can set this timer feature for other equipment such as lighting, spa, or spa
jets. Equipment can be set to be on for one minute or 24 hours. The Egg Timer program is factory set to switch
off after 12 hours. You also have the option to use the "Don't Stop" feature to run a circuit continuously until
manually switched off.
Please note that in the event of a power failure, the Egg Timer feature will not switch the circuit back on. Use
the "Service" mode button to turn the equipment back on manually. Refer to "Mode button," page 5 for details.
Note: When running the filter pump continuously during a new pool start up, it is recommended to use the
"Service" mode, which will automatically restart the filter pump in the event of a power failure.
To set the Egg Timer feature:
MENUsSCHEDULESwSPA (POOL)
SPA
0
POOL
0
AUX 1
0
AUX 2
0
SPA
0/0
Mode: None (New)
SPA
1/1
Mode: Egg Timer
Time: 05:00
EASYTOUCH
PL4/PSL4 Control Systems User's Guide
®
Right button: Select the Spa or Pool circuit. You can also select any of the available
circuits. The generic circuit names are: Spa, Pool, Aux 1-3, and Feature 1-2.
Right button: Select Mode if there are existing programs. Skip this step to create a new
program.
Up/Down button: Select New to create a new program.
Right button: To create a new program and enter the "Mode" settings.
Up/Down button: 1/1 indicates that this circuit has one program. You can create a total
of 4 programs. If there are existing programs assigned to this circuit, use these buttons
to view and select the existing program settings.
Right button: To select the "Egg Timer" settings.
Right button: Move to the time settings.
Up/Down and Right buttons: Set the hour and minutes for the program to run. The
count down time can be set from 00:01 to 23:59 and Don't Stop. The "Don't Stop"
feature allows the circuit to run continuously until manually switched off.
Press the Menu button to save the settings and to return to the Schedules menu
options. Press the button again to return to the main menu options or press again to
return to the main screen.