36
IntelliFlo VS and VSF+SVRS Settings (Continued)
Pump #1 Type
Type: VS
Pump #1
1/4
RPM: 1200
Circuit:
[ POOL
]
Pump Type
Flow/Speeds
Status
Pump #1 Type
Type: VSF+SVRS
Pump #1
1/4
GPM:30 PSI: 15
Circuit:
[ NONE
]
Pump #1
1/4
GPM:30 PSI: 15
Circuit:
[ AUX 1
]
GPM: 30
1200 RPM 12 W
Watts: 10
Status: GOOD
EASYTOUCH
PL4/PSL4 Control Systems User's Guide
®
INTELLIFLO VS SPEEDS SETTING:
Down button: Choose Speeds.
Right button: Access the IntelliFlo VS speed (RPM) settings for Pump #1.
Up/Down button: Select the circuit number 1 of 4 (1/4).
Right button: Move to RPM to change the pump speed.
Up/Down buttons: Set speed of the pump from 400 to 3450 RPM in increments of
10 RPM. The default speed for each circuit correspond to the four speed buttons on
the IntelliFlo VS control panel is: Speed 1 button 750 RPM, Speed 2 button 1500
RPM, Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM.
INTELLIFLO VSF+SVRS FLOW RATE SETTING:
Down button: Choose Flow/Speeds.
Right button: Access the IntelliFlo VSF+SVRS speed (RPM/GPM) settings for Pump
#1.
Up/Down button: Select the circuit number 1 of 4 (1/4).
Right button: Move to GPM to change the pump flow rate.
Up/Down button: Select RPM or GPM. Press Up/Down button to toggle between
RPM and GPM and pressure setting (PSI).
Right button (GPM): Move to GPM pump flow rate.
Up/Down button: Set speed of the pump from 15 to 130 GPM. The default flow
rate is 30 GPM. The preset speed for each button is: Speed 1 button 1100 RPM
(30 GPM), Speed 2 button 1500 RPM, Speed 3 button 2350 RPM, and Speed 4
button 3110 RPM.
Right button (GPM/PSI): Move to PSI (pounds per square inch) pressure setting.
Up/Down button: Select the pump pressure setting from 1 to 30 PSI. See above for
equivalent default RPM/GPM (speed/flow rate).
VS and VSF+SVRS CIRCUIT SETTING:
Right button: Move to the circuit names.
Up/Down buttons: Assign the pump circuit: NONE, SPA, POOL, AUX 1-3,
FEATURE 1-2, HEATER, POOL HEATER, SPA HEATER, FREEZE, POOL/SPA, and
SOLAR/HEAT.
Right button: Press the Up arrow button and go to the next circuit page settings
(2/4) and repeat the previous steps.
When finished setting up the circuits, press the Menu button to save the settings and
to return to the Settings menu options. Press the button two times to return to the
main screen.
INTELLIFLO VS STATUS SETTING:
Down button: Choose STATUS.
Right button: View the current IntelliFlo VS pump status.
Menu: Press MENU to exit.