Error Code 02 Is Indicated (= Feed Table Does Not Lift) - Horizon Fitness PF-P330 Manual

Table of Contents

Advertisement

4: Mechanical Troubleshooting
4-2
Error Code 02 Is Indicated
The error code 02 is indicated when the
feed table upper limit sensor B06 does not
turn ON within 7 seconds after the signal to
lift the table has been sent.
The height detect lever of the sensor
B06 is raised.
Sensor
B06
Height Detect Lever
Fulcrum
On the back of the height detect lever, a thin iron chip
is attached. When the lever is raised by the sheets
and detected by the sensor B06, the feed table stops.
Check the followings:
1.
Installation and function of the height detect
lever.
2.
The installation of the iron chip on the back of
the height detect lever, and the B06.
3.
Wiring and connection between the B06 and
Pin1, 2 of CON10 on QPM192.
(= Feed Table Does Not Lift)
The upper guide is raised.
S01
The upper guide is held by a magnet. When the
upper guide is raised and remains there, the table
upper limit switch S01 works and stop the feed table.
Check the followings:
1.
An object on the feed table raises the upper
guide.
2.
An object sticks on the magnet that is installed
under the upper guide, and it raises the upper
guide.
3.
The upper guide is deformed and positions
apart from the S01.
4-2: Error Code 02 Is Indicated
4
Mechanical Troubleshooting
Table upper limit switch S01
malfunctions.
Upper Guide
Magnet
Check the followings:
1.
S01 is installed correctly as shown in Section
[3-8: Table Upper Limit Switch S01 Position
Adjustment] , Fig.3.
2.
When raising the upper guide manually, the
LED L9 on QPM192 lights OFF.
3.
When raising the upper guide manually and
pushing down the actuator of the S01, L9
illuminates.
4.
Wiring and connection between the S01 and
Pin3,4 of CON3 on QPM192 is OK.
The feed table Up/Down mechanism
malfunctions.
See Section [4-1: Error Code 01 Is Indicated] and
check the same heading.
QPM-192
L9
NC
ORN
CON3
S01
3
NO
YEL
C
4
4-3

Advertisement

Table of Contents
loading