4: Mechanical Troubleshooting
4-12 Error Message "Close Buckle" Is Shown
The buckle cover sensor B03 is
installed incorrectly.
Buckle Fixing Lever
B03
Check the followings:
1.
The buckle fixing lever is fully closed.
2.
The fixing screw on the sensor B03 is fully
tightened.
3.
The sensor connector is fully connected.
4.
Magnet is installed correctly.
The buckle cover sensor B03
malfunctions.
QPM-192
CON2
6
BRN/WHT
8
Magnet
Check the followings:
1.
Remove the magnet that holds the buckle
fixing lever, and put it on the sensor B03
directly. Check that the LED L7 on the
QPM192 illuminates.
2.
Wiring and connection:
- Between the B03 and CON3 on QPW422
- Between the Pin6, 8 of CON1 on QPW422
and Pin6, 8 of CON2 on QPM192
(Even though it is closed)
QPW-422
B03
CON1
BLK
6
1
1
8
2
2
CON3
Buckle Cover
Sensor