4: Mechanical Troubleshooting
4-10 Motor Does Not Drive
Blower motor M05 does not drive.
X10 Q04
SSR
K02
3A
S00
1 2
X11
X14
1
1
2
2
3 3
[Driving the Blower Motor M05]
Turn OFF the power switch. Keep pressing the [5]
button on the numeric key pad and turn ON the power
switch. The blower, valve, clutch and table Up/Down
motor repeat the cycle of feeding operation. (To stop,
turn OFF the power switch.)
Check the followings:
1.
The connecter between the M05 and the
machine is fully connected.
2.
Circuit protector Q04 is not actuated.
3.
The voltage between the BL terminal X10 and
X11 is 115/230VAC.
4.
When the air amount is set at maximum, the
voltage between the Pin1 and 2 of terminal
X14 is about 115/230VAC.
The motor for cleaner shown as 13 to the right is
used for the blower motor.
This motor has limited longevity and needs to be
replaced by about 1,000 hours. This is because
that the carbon brush inside the motor is worn out.
The blower motor can not be replaced singly.
Blower Motor
Replace the whole blower box.
M05
6
4
3
M05
13
2
5
Fig.1 Blower Box