Qpm-192 Led Layout - Horizon Fitness PF-P330 Manual

Table of Contents

Advertisement

6: Electrical Circuit
6-4
Control P.C.B. QPM-192
6-4-2

QPM-192 LED Layout

L9
L8
1
CON10
1
1
1
CON9
CON8
CON4
CON5
BZ
DSW1
VR2
C10
QPM-192
C11
IC2
CPU
TP4
TP5
1
1
1
CON10
CON2
CON1
5V
GND
1
1
CON2
CON1
LED Illuminating Condition
1
L1
Sensor A on the first stopper encoder P.C.B. QPW-422 does not receive light.
VR1
L2
Sensor B on the first stopper encoder P.C.B. QPW-422 does not receive light.
L3
The first buckle chute home position sensor B01 is ON
L4
Sensor A on the second stopper encoder P.C.B. QPW-422 does not receive light.
L5
Sensor B on the second stopper encoder P.C.B. QPW-422 does not receive light.
L6
The second buckle chute home position sensor B02 is ON
L7
Buckle cover sensor B03 is ON.
L8
Sheet detect sensor B08 is ON.
L9
Table upper limit switch S01 is ON.
L10
Count sensor (receiver) B05 does not receive light (sheet is passing.)
L11
Sheet upper limit sensor B06 is ON.
L12
Table lower limit sensor B07 is ON.
6-6