Connecting ac Power to an AX100SC Storage System
When powerup is complete (usually in 5-6 minutes), the SP
Boot/Fault light goes off. If the storage system does not power up
within several minutes, refer to the "Troubleshoot" section on the
AX100 support website or the AX100-Series Documentation CD.
Rear Lights
SP A
FE 0
FE 1
Power
SP A Boot/Fault
Power Supply A Fault
EMC2955
Front Lights
Fault
Disk Activity
Power
EMC2934
AX100SC Storage-System Lights (LEDs)
Figure 12
If the amber System Fault light is on after powerup, a fault exists
somewhere in the storage system. If the amber light specific to a
power supply, SP, or disk is on, then that part is faulted.
CAUTION
!
Press the power button only briefly to power up the storage system.
Pressing the power button for more than four seconds while the
storage system powers up may affect initialization parameters.
AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a Solaris Server
34