Pocket mount
Hide thumbs Also See for Sivoia QS roller 100:

Advertisement

Sivoia
QS
®
roller 100
TM
pocket mount
Installation
Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lutron Electronics Sivoia QS roller 100

  • Page 1 Sivoia ® roller 100 pocket mount Installation Instructions...
  • Page 2: Installation Instructions

    #2 Phillips Screwdriver ® Box contents: (2) Pocket sub-brackets (1) Sivoia QS roller 100 Left and right side shade bracket (attached) (1) 4 pin terminal block (2) Extra retaining screws (#6 x 1/4 in (#6 x 6 mm) Phillips head screws ®...
  • Page 3 CAUTION: Risk of bodily injury, follow all installation instructions. Notes: The Sivoia QS roller 100 must be used only with window systems approved by Lutron. • There must be a clearance of at least 1.3 feet (0.4 meters) between the fully lowered system and any •...
  • Page 4 Confirm System Dimensions Package Label Compare system dimensions on the package label with the window dimensions to verify appropriate window/shade combination. This information can also be found on the shade tube by lowering the fabric down far enough to expose the tube.
  • Page 5 Pre-drill pocket for cable run Determine where to drill for cable access into pocket. See options below. Cable should exit from wall, ceiling or jamb on EDU side of pocket. Note: Hole diameter should be large enough to • allow adjustment of pocket during installation without pinching the wire.
  • Page 6 Pre-drill pocket for cable run (continued) NOTICE: When installing top/backcover, pocket, or headrail with a motorized window shade the following steps must completed. Figure A Description When installing top/backcover, pocket, or headrail with a motorized window shade, a grommet must be used to protect the power wire if it is run through the cover.
  • Page 7 Mount Pocket If endcaps are being used, slide them in the ends of the pockets. Endcaps should only be used if the pocket ends will be exposed. Mount pocket securely using appropriate fasteners. CAUTION: Risk of bodily injury from falling heavy object. The sub-brackets for each pocket must be mounted to support a weight of at least 300 pounds (136 kg).
  • Page 8 Mount sub-brackets Use fabric alignment holes to Pocket width position the sub-bracket right Pocket width to left. The fabric alignment ceiling Ceiling holes will line up with the out- side edge of the shade tube. Note: Fabric edge may not line up with the edge of tube.
  • Page 9 Mount sub-brackets (continued) Mount sub-brackets using appropriate fasteners. CAUTION: Risk of bodily injury from falling heavy object. The sub-brackets for each shade tube must be mounted to support a weight of at least 300 pounds (196kg). The fasteners provided with the sub-brackets may not be appropriate for use in all applications.
  • Page 10 Wire 4-pin terminal block Strip 2 in (50 mm) of the jacket off the cable run from the wall. Wire the 4-pin terminal block (provided) to the cable using a screwdriver. Make sure to tighten the screws tightly and that no insulation is inside of the terminal block.
  • Page 11 Mount shade to sub-bracket NOTICE: Shades wider than 4 ft (1.2 m) require two people to install. Note: If installing a coupled shade system, install the shade with the EDU first. Note: Leave protective wrapping on shade during installation. Remove retaining screws from shade brackets.
  • Page 12 Center and secure shade Move the shade left or right until centered. CAUTION: Risk of ceiling bodily injury ceiling Shade must be se- cured during adjustment procedures. Shade is not secured to the wall during the adjustment procedure. Extreme movement from side-to- side may cause shade to fall.
  • Page 13 Adjust shade level Turn leveling screw to raise or lower idler side ceiling ceiling of shade until level. Adjust shade projection from window so that it clears any window trim or hardware when operating. It may be necessary to remove the shade from the pocket to make this adjustment.
  • Page 14 Connect terminal blocks Plug 4-pin terminal block on cable into EDU terminal block (a cable tie can be used to secure the terminal blocks together). Dress wires to ensure fabric does not rub while the shade is moving. Page 13 Sivoia roller 100 Pocket Mount...
  • Page 15 Secure and check the shade 10.1 Use the programming stylus to run the shade up and down using the adjustment buttons ( ), re-level if needed. NOTICE: Pay careful attention to the shade roll up to ensure that it does not telescope extremely to one side or the other.
  • Page 16 Setting limits from the EDU Setting the open limit from the EDU The open and close limits define the top and bottom of the shade, and are used to determine which direction the shade must turn in order to raise or lower. Refer to the keypad’s instruction sheet to set the limits remotely.
  • Page 17 Setting limits from the EDU (continued) Setting the close limit from the EDU 11.4 Tap the “close limit button” ( ) . The green LED on the roller 100 EDU will turn on steady, Green LED indicating that the EDU is Tap the in “set close limit mode”.
  • Page 18 Verify Limits 12.1 Verify the open limit by double-tapping the open limit ( ) button. The shade will travel to the open limit. 12.2 Verify the close limit by double-tapping the close limit ( ) button. The shade will travel to the close limit. Page 17 Sivoia roller 100...
  • Page 19: Verify Communications

    Verify communications 13.1 Enter “link diagnostics mode” by pressing and holding the “close limit button” ( ) on the EDU for 5 seconds. The green LED will flash quickly for two seconds then turn Green LED on steady, indicating the EDU is ready to begin verifying Press and hold the communications with...
  • Page 20 Programming restoring default settings Returning an EDU to its factory default setting Returning an EDU to its factory defaults will clear out any programming to keypads, but will not affect the limits. 14.1 Press and hold the “close limit button” ( ) on the EDU for 5 seconds.
  • Page 21: Troubleshooting

    Troubleshooting Symptom Solution EDU is not powered - check EDU Power by unplugging and re-plugging in EDU. Shade will not move using adjustment LED should flash for 5 seconds. buttons on EDU. Shade is caught on something - free shade. Limits have been set incorrectly - refer to “Set open limit”...
  • Page 22: Limited Warranty

    Limited Warranty SCOPE Replacement parts for the System provided by This limited warranty (“Warranty”) covers the Lutron or, at its sole discretion, an approved ven- Lutron supplied (a) Sivoia QS Shade System dor may be new, used, repaired, reconditioned, ® (“Sivoia QS Shade System”), (b) Sivoia QED and/or made by a different manufacturer.
  • Page 23 ANY OTHER PARTY, AND EVEN IF LUTRON Lutron, the Sunburst logo, and OR SUCH OTHER PARTY WAS ADVISED OF Sivoia QS are registered trademarks of THE POSSIBILITY OF SUCH DAMAGES. Lutron Electronics Co., Inc. Page 22 Sivoia roller 100 Pocket Mount Installation instructions ®...
  • Page 24: Technical Assistance

    90 rue de Villiers Lutron GL Ltd. 92300 Levallois-Perret, email: shadinginfo@lutron.com 15 Hoe Chiang Road France #07-03 Tower Fifteen Tel: +33.(0)1.41.05.42.80 Singapore 089316 ©2008 LUTRON Electronics Co., Inc. Fax: +33.(0)1.41.05.01.80 Tel: +65.6220.4666 P/N 045-133 REV. A FREEPHONE: 0800.90.12.18 Fax: +65.6220.4333 lutronfrance@lutron.com lutronsea@lutron.com Spain-Madrid EUROPEAN Tel: +34.91.567.84.79...

Table of Contents