Lutron Electronics Sivoia QS roller 100 Installation Instructions Manual page 20

Pocket mount
Hide thumbs Also See for Sivoia QS roller 100:
Table of Contents

Advertisement

14
Programming
Returning an EDU to its factory default setting
Returning an EDU to its factory defaults will clear out any programming to keypads, but
will not affect the limits.
14.1
Press and hold the "close limit
button" ( ) on the EDU for 5
seconds. The green LED on
the EDU will flash quickly for two
seconds then turn ON steady.
14.2
Press and hold the "open limit
button" ( ) for 5 seconds. The
green LED on the EDU will flash
then turn ON steady.
14.3
Press and hold the
"clockwise button" ( ) for
5 seconds. The green LED
on the EDU will flash then
turn ON steady.
14.4
Press and hold the
"counterclockwise button" ( ) for
5 seconds. The LED on the EDU
will flash blue briefly, and then
the EDU will reset. The EDU is
now restored to factory default
settings. The limits will not
be affected.
Page 19
Sivoia
QS
®
|
restoring default settings
Flashing green LED
Press and hold the
close limit button
for 5 seconds
Flashing green LED
Press and hold the
open limit button
for 5 seconds
Press and hold the
clockwise button
for 5 seconds
Flashing green LED
Press and hold the
counterclockwise button
for 5 seconds
LED will flash blue
roller 100