Functions Menu - CAME VER-PLUS Series Installation Manual

Garage-door operator
Table of Contents

Advertisement

Functions menu

IMPORTANT! Start programming by fi rst performing the TOTAL STOP (F1) and CALIBRATING TRAVEL
(A3) functions
Only program functions when the operator is stopped.
 
You can save up to 250 users.
F 1
Total stop [1-2]
F 2
Input [2-CX]
F 3
Input [2-CY]
F 5
Safety test
Maintained
F 6
action
Control mode
F 7
on 2-7
Control mode on
F 8
2-3P
Obstruction
F 9
detection with
motor stopped
NC input – Door stops and excludes any automatic closing; to resume
movement, use the control device. The safety device is inserted into [1-2], if
unused, select 0.
OFF= Deactivated (default) / ON= Activated
NC input – Can associate: C1 = reopening during closing by photocells, C2
= reclosing during opening by photocells, C3 = partial stop, C4 = obstruction
wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing
during opening by sensitive safety-edges, r7 = reopening during closing for
8K2 resistive, sensitive safety-edges, r8 = reclosing during opening for 8K2
resistive, sensitive safety-edges.
OFF = Deactivated (default) / C1 / C2 / C3 / C4 / C7 / C8 / r7 / r8
The C3 setting appears only if F19 is active.
NC input – Can associate: C1 = reopening during closing by photocells, C2
= reclosing during opening by photocells, C3 = partial stop, (appears only if
F19 is > 1), C4 = obstruction wait, C7 = reopening during closing by sensitive
safety-edges, C8 = reclosing during opening by sensitive safety-edges, r7
= reopening during closing for 8K2 resistive, sensitive safety-edges, r8 =
reclosing during opening for 8K2 resistive, sensitive safety-edges.
OFF = Deactivated (default) / C1 / C2 / C3 / C4 / C7 / C8 / r7 / r8
The C3 setting appears only if F19 is active.
After every opening or closing command, the board will check whether the
photocells are working properly.
OFF= Deactivated (default) / 1=CX / 2=CY / 4=CX+CY
The door opens and closes by keeping the button pressed. Opening button on
contact 2-3P and closing button on contact 2-7. All other control devices, even
radio-based ones, are excluded.
OFF= Deactivated (default) / ON= Activated
The control device connected to 2-7 performs the step-step command
(open-close-invert), sequential (open-stop-close-stop), only open or only close.
0 = Step-step (default) / 1 = Sequential / 2 = Open / 3 = Close
The control device connected to 2-3P performs a partial opening (1) or comple-
te opening of the door (2).

The partial opening time is adjusted by function F 36.
1 = Partial opening (default) / 2 = Open
The door closed, open or after a total stop, the gear motor stay idle if the safety
devices, that is, the photocells detect an obstruction.
OFF = Deactivated (default) / ON = Activated

Hide quick links: