CAME VER-PLUS Series Installation Manual page 25

Garage-door operator
Table of Contents

Advertisement

Slow-down
F30
speed
Calibration
F33
speed
Travel
F34
sensitivity
Slow-down
F35
sensitivity
Adjusting the
F36
partial opening
Adjusting the
F41
opening slow-
down
Adjusting the
F42
closing slow-
down
Adjusting
F44
the closing
approach
Slowed-down
F47
start when
closing
Managing
F49
the serial
connection
F50
Saving data
F51
Uploading date
Setting the door's opening and closing slow-down speed, calculated as a
percentage.
20 = Minimum speed / 40 = 40% of the motor's speed (default) / 60 =
Maximum speed
Setting the gear motor's calibration speed, calculated as a percentage.
30 = 30% of the maximum speed /... /50 = 50% of the maximum speed
(default) /... / 60= 60% of the maximum speed
Adjusting obstruction detection sensitivity during door travel.
10 = Maximum sensitivity /... / 100= Minimum sensitivity (default)
Adjusting obstruction detection sensitivity during slow-down.
10 = Maximum sensitivity /... / 100= Minimum sensitivity (default)
Adjusting, as a percentage of total door travel, the door's partial opening.
10 = 10% of the door travel /... / 40 = 40% of the door travel (default) /...
/ 80= 80% of the door travel
Percentage adjustment of the total door travel, of the opening slow-down
starting point.
1 = 1% of the door travel / ... / 5 = 5% of the door travel (default) / ... / 60
= 60% of the door travel
Percentage adjustment of the total door travel, from the closing slow-down
starting point.
1 = 1% of the door travel / ... / 15 = 15% of the door travel (default) / ... /
60 = 60% of the door travel
Adjusting, as a percentage of the total door travel, of the closing approach
starting point.
1 = 1% of the door travel / ... / 10 = 10% of the door travel (default)
Adjusting, as a percentage of the total door travel, of the starting of the closing
slow-down.
OFF = Deactivated / 1 = 1% of the door travel (minimum) / ... / 5 = 5% of the
door travel (default) / ... / 50 = 50% of the door travel (maximum)
For enabling the CRP (Came Remote Protocol).
0 = Deactivated / 3 = CRP (default)
Saving users and settings saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the
control board.
0 = Deactivated (default) / 1 = Activated
Uploading data saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the
control board.
0 = Deactivated (default) / 1 = Activated