General Installation Indications; Cable Type And Minimum Thicknesses - CAME VER-PLUS Series Installation Manual

Garage-door operator
Table of Contents

Advertisement

GENERAL INSTALLATION INDICATIONS

⚠ Only skilled, qualifi ed staff must install this product.

Cable type and minimum thicknesses

Connection
Control panel power supply 230 V AC
Flashing light
Command and control devices
TX Photocells
RX photocells
When operating at 230 V and outdoors, use H05RN-F-type cables that are 60245 IEC 57 (IEC) compliant;
whereas indoors, use H05VV-F-type cables that are 60227 IEC 53 (IEC) compliant. For power supplies up to
48 V, you can use FROR 20-22 II-type cables that comply with EN 50267-2-1 (CEI).
To connect the antenna, use the RG58 (we suggest up to 5 m).
 For paired connection and CRP, use a UTP CAT5-type cable (up to 1,000 m long).
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual
power draw of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated
according to the actual power draw and distances. For connecting products that are not contemplated in this
manual, see the literature accompanying said products
cable length
< 20 m
2
3G x 1.5 mm
2 x 0.5 mm
2 x 0.5 mm
2 x 0.5 mm
4 x 0.5 mm
20 < 30 m
2
3G x 2.5 mm
2
2
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ver10dmsVer13dms

Table of Contents