Description Of Functions - CAME VLR01DX Installation Manual

Shutter operator
Hide thumbs Also See for VLR01DX:
Table of Contents

Advertisement

Programming the features
Before programming functions, release the gearmotors, manually close the shutter leaves and re-lock the gearmotors.
DIP1
DIP2
DIP3
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
Self-learning of the gate-leaf travel
Select the DIPs as shown and press the PROG key on the
board.
To calibrate the travel the leaves must be closed.
The leaves will perform a series of maneuvers to establish the
limit switch points.
During calibration the red LED flashes. Once the calibration is
done the buzzer sounds off for one second.
If calibration was not successful, the LED flashes quickly and
the buzzer sounds 4 times.
The
self-learning
procedure
by pressing the PROG key .
⚠ To configure for one swing-leaf, connect the operator to
MOTOR2.
Partial opening from button
Use the buttons to move the leaves to the desired position
Only consider the first leaf's opening angle. During the first
maneuver, the second leaf will memorize the opening angle
of the first leaf.
Select the DIP switches as shown or press PROG on the
control board.
Once memorized the buzzer sounds off for one second.
If the partial opening angle does not come within the
minimum and maximum default-set limits (fro 10% to 50%
of the travel), upon sending the next command the opening
angle will automatically set to the closest level.
DIP4
OFF
Self-learning of the gate-leaf travel
ON
Partial opening from button
ON
Button-activated maintained action
OFF
Transmitter activated partial opening
OFF
OPEN-STOP from trasmitter
OFF
CLOSE-STOP from transmitter
OFF
Transmitter activated OPEN-STOP-CLOSE-STOP
OFF
Weather unit
OFF
Deleting memorized transmitters and weather units
ON
Increasing the maneuvering speed
ON
Reducing the slow-down speed
ON
Adjusting the sensitivity
ON
Slowed-down start when closing
ON
Immediate closing in case of a power outage
ON
Resetting parameters
can
be
interrupted

Description of functions

To disable the function: with the DIP switches set as shown,
press again the PROG key on the control boar.
Button-activated maintained action
Select the DIP switches as shown or press PROG on the
control board.
Once memorized the buzzer sounds off for one second.
To
restore
the
PROG again. The LED flashes and the buzzer sounds off
twice.
⚠ The opening button connected to 2-3 (NO contact) is
default set to the OPEN-STOP function.
If I enable maintained action from a button, I cannot enable
partial opening from a button and neither from a transmitter.
You can memorize up to a maximum of ten different
radio codes.
Partial opening using transmitter (only if already saved to
a button).
Select the DIP switches as shown or press PROG on the
control board. The red LED flashes. Within ten seconds press
the button on the transmitter you wish to memorize. Once
memorized the buzzer sounds off for one second.
If the key has already been memorized, the LED will flash
quickly and buzzer will flash four times.
default
parameters
press

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlr02Vlr01sx

Table of Contents