  • Page 1 SHUTTER OPERATOR FA00135-EN INSTALLATION MANUAL VLR01DX - VLR01SX - VLR02 English...
  • Page 2 HIS PRODUCT SHOULD ONLY BE USED FOR THE PUR DEVICE ANY DIRECT COMMANDS WHETHER BUT POSE FOR WHICH IT WAS EXPLICITLY DESIGNED NY OTH . CAME S. TONS TOUCH PANELS AND SO ON MUST BE INSTALLED ER USE IS DANGEROUS...
  • Page 3 RELEASE THE OPERATOR AND DO NOT USE IT UNTIL A COMMAND IN MAINTAINED ACTIONS KEEP CHECKING • C SAFETY CONDITIONS HAVE BEEN RESTORED UT OFF THAT THERE ARE NO PERSONS WITHIN THE OPERATING THE POWER SUPPLY BEFORE RELEASING THE OPERATOR RANGE OF ANY MOVING PARTS UNTIL THE COMMAND IS •...
  • Page 4: Reference Regulations

    This product complies with the current regulations mentioned in the declaration of conformity. DESCRIPTION This product has been designed and built by CAME S.p.A. in compliance with current legal safety standards. The operator is composed of a part made of cast aluminium inside of which works the irreversible gearmotor plus an aluminium casing.
  • Page 5 Technical data Type VLR01DX - VLR01SX VLR02 command Protection rating (IP) Power supply (V - 50/60 Hz) 230 AC 230 AC Motor power supply (V) 24 DC 24 DC Current draw (A) 3 max 6 max Power (W) Opening time at 180° (s)
  • Page 6: Drilling Template

    Master/Slave connection cable Transmission arms (see following tables) Arm slide-guides Manual release lever Protective carter for operators Continuous protective carter (OPTIONAL, item VLR04) End caps 10. Carter closing/connecting strips 11. Emergency battery device (OPTIONAL, item VLR05) 12. Drilling template VLR02 VLR01SX VLR01DX...
  • Page 7 One or two-leaved single panel retractable shutter Unfoldable type of transmission arm VLR07 VLR08 A - Minimum space between the inner fi xture and the shutter 90 / 110 (without batteries / with VLR05 batteries) B - Bay width (min./max.) One leaf, without VLR01xx batteries 500 / 1050 500 / 1050...
  • Page 8: Preliminary Checks

    One or two-leaved jointed double-paneled shutter Unfoldable type of transmission arm VLR08 VLR09 A - Minimum space between the inner fi xture and the shutter B - Bay width (min./max.) One leaf, without VLR01xx batteries 500 / 1050 500 / 1050 One leaf, with VLR01xx+VLR05 batteries 750 / 1050 750 / 1050...
  • Page 9 INSTALLING The following illustrations are examples. It is up to the installer to find the most suitable solution. The template features the indications for use on both the right and left. Tracing the holes Rest the template against the shutters and the bay side panel of the bay and mark the holes using a pencil;...
  • Page 10 Fastening the operator If the bay width is less than the dimensions of the operator base(s), cut off any excess ❸. The emergency batteries (item VLR05) may not be fitted. Fit the operator using suitable screws and dowels. For the two-leaf swing configuration, install the MASTER operator ❹...
  • Page 11 Cut the slide rails to the required length, leaving a minimum clearance at the ends . One or two-leaf single-panel shutter One or two-leaved jointed double-paneled shutter Fit the arm skid into the slide rail (see Fit the guide to the shutter and check that it is level and that the skid slides smoothly.
  • Page 12 VLR02 operator Master and Slave connection Attach the cable clips ❻. Connect the Slave gearmotor to the Master operator using the wired cable ❼ on the MOTOR1 terminal. In this way, the right-hand leaf will open first. If you need the left-hand leaf to open first while keeping the Master to the right, swap the MOTOR1 and MOTOR2 connectors.
  • Page 13: Description Of Parts

    ELECTRICAL CONNECTIONS AND PROGRAMMING The control panel is powered by 230 V AC, with 50/60Hz frequency. The control devices and accessories run on 24 V. ⚠ The accessories must never exceed 15 W in total. Fuses Type Line (mA) Accessories (mA) Description of parts 230 V AC power-supply terminals 10.
  • Page 14 AFTER CUTTING OFF THE MAINS POWER. N.B.: the basic control board recognises them only when it is powered up. AF card CRP - Came Remote Protocoll. Connection to the home-automation system. OPEN-STOP function (NO contact) CLOSE-STOP function (NO contact) ⚠...
  • Page 15: Safety Devices

    Safety devices REOPENING DURING CLOSING (NC). During the leaf closing phase, opening the contact inverts the movement until the leaves are fully open. If contacts 2-CX are unused, they should be bridged. 001AF43S - 001AF868 card fitting AF card...
  • Page 16: Description Of Functions

    Programming the features Before programming functions, release the gearmotors, manually close the shutter leaves and re-lock the gearmotors. DIP1 DIP2 DIP3 DIP4 Description of functions Self-learning of the gate-leaf travel Partial opening from button Button-activated maintained action Transmitter activated partial opening OPEN-STOP from trasmitter CLOSE-STOP from transmitter Transmitter activated OPEN-STOP-CLOSE-STOP...
  • Page 17: Adjusting The Sensitivity

    OPEN-STOP from transmitter control board. The LED stays on and the buzzer sounds off for 1 s. Select the DIP switches as shown or press PROG on the control board. The red LED flashes. Within ten seconds press To return to the default settings, press the PROG key again. the button on the transmitter you wish to memorize.
  • Page 18: Final Operations

    FINAL OPERATIONS Fasten the end caps using the supplied screws. Fit the snap-in casing onto the gearmotor and secure it using the supplied screws. With two-leaved installations like with the Voilà VLR02, whose window-bay width exceeds 970 mm, we suggest also fitting the VLR04 covering cross-piece so that it also covers the Master/Slave connection.
  • Page 19: Dismantling And Disposal

    CAME S.p.A. applies a certified Environmental Management System at its premises, which is compliant with the UNI EN ISO 14001 standard to ensure environmental protection. Please continue safeguarding the environment. At CAME we consider it one of the fundamentals of our operating and market strategies. Simply follow these brief disposal guidelines:...
  • Page 20 CAME S.p.A. CAME S.p.A. Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c 31030 Dosson di Casier Dosson di Casier 33079 Sesto al Reghena Sesto al Reghena Treviso Treviso - Italy Pordenone Pordenone - Italy (+39) 0422 4940 (+39) 0434 698111...