To set the peripheral number from 1 to 255 for each control board when a
system is fi tted with several operators and features the CRP (Came Remote
Protocol) connection system.
1 ----> 255
For setting the communication speed used in the CRP (Came Remote Protocol)
connection system.
0 = 1200 Baud / 1 = 2400 Baud / 2 = 4800 Baud / 3 = 9600 Baud / 4 =
14400 Baud / 5 = 19200 Baud / 6 = 38400 Baud (default) / 7 = 57600
Baud / 8 = 115200 Baud
RIO-EDGE wireless safety-device associated to one of the following available
functions: P 7 = reopening during closing, P 8 = reclosing during opening, P
0 = Total stop.
For programming, see the instructions that come with the accessory.

This function only appears if the RIOCN8WS card is plugged into the
control board.
OFF = Deactivated (default) / P0 / P7 / P8
RIO-EDGE wireless safety-device associated to one of the following available
functions: P 7 = reopening during closing, P 8 = reclosing during opening, P
0 = Total stop.
For programming, see the instructions that come with the accessory.

This function only appears if the RIOCN8WS card is plugged into the
control board.
OFF = Deactivated (default) / P0 / P7 / P8
RIOPH8WS wireless safety-device associated to one of the following available
functions: P 1 = reopening during closing; P 2 = reclosing during opening; P 3
= partial stop; P 4 = obstruction wait.
For programming, see the instructions that come with the accessory.

This function only appears if the RIOCN8WS card is plugged into the
control board.
OFF = Deactivated (default) / P1 / P2 / P3 / P4
RIOPH8WS wireless safety-device associated to one of the following available
functions: P 1 = reopening during closing; P2 = reclosing during opening; P3
= partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.

This function only appears if the RIOCN8WS card is plugged into the
control board.
OFF = Deactivated (default) / P1 / P2 / P3 / P4
Enter up to 250 users and associate to each of them one of the available
functions. This must be done via transmitter or other control device (see
"ENTERING USERS WITH ASSOCIATED COMMAND paragraph).
1 = open-close (step-step) / 2 = open-stop-close-stop (sequential) /
3 = only open / 4 = partial opening
Deleting a single user
Deleting all users.
OFF = Deactivated / ON = Delete all users