C. Remove the fastening screw② of the transfer base cover
(right)① and assemble the sensor setting axis③ at the
same place.
D. Insert the sensor setting plate④ into the sensor setting
axis③ and then tighten the screw⑤.
E. Remove hammer plate
If the sewing machine is attached with the special lapel
cutter, but is not going to be used, the hammer plate shall
be removed.
Loosen the bolt① and remove the hammer plate②.

2) Install solenoid valve

A. Install the solenoid valve② on the lower part of the table
by using screw nails①.
B. Remove the plug④ of the main solenoid valve③ and
attach the nipple⑤.
C. Connect nipple ⑤ and nipple⑦ using air hose⑥ (ф4).
D. Connect air hoses
figure.